![Dante DLV4300B Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/dante/dlv4300b/dlv4300b_installation-and-operation-manual_3459516024.webp)
24
To Set Up preset:
Preset is a scene set in advance, whatever position camera is on, when user Sets up presets,
speed dome or receiver/driver will move to preset position, at the same time, camera lens
also auto adjust image size, preset image would be displayed on screen automatically,
matrix system supports max 128 presets.
As a result of mechanism structure, speed dome camera can Set up preset quickly, but P/T
only move to preset position slowly according to P/T speed.
“Call” key on keyboard can Set up preset, the operation procedure are following:
1) Set up camera which user need on monitor;
2)Input preset number( 1-128 )
3) press “call” key to Set up preset
Assistant Switcher Control:
“F1/On” or “F2/On” on keyboard is to control assistant switcher, receiver/driver, speed
dome… in matrix system, please refer to user manual for switchers in detailed
The procedure are following:
1) Set up camera which user need on monitor
2) input switcher number through keyboard
3) Press F1/On key, assistant switcher would be open.
4) Press F2/OFF key, assistant switcher would be closed.
Run auto switch group images:
When user operation this function, a series of set images would be displayed on one
monitor continuously, user not only set signal monitor to switch a group of images in matrix
system, but also user may set many monitors to switch a group of images.
The pre-condition for this operation is that switched images on appointed monitor must be
set. To press “SEQ” key, a group of images would be switched automatically according to
program.
1.
To input switching group number 1-32 though keyboard.
2.
To press “SEQ” key to carry out operation
3.
If user want to stop it, press “shift+SEQ” key.
Set Up Synchronous Switch:
To Set up synchronous switch is to switch a group of images on a group of monitor one by
one, user may set synchronous switch though menu.
The procedures are following:
1)
Input synchronous switch number 1-16 through keyboard.
2)
Press “GRP” key to carry out this operation.
3)
If user want to stop it, press “shift+GRP” key.
Содержание DLV4300B
Страница 12: ...12...
Страница 20: ...20...
Страница 37: ...37 4 Software Run To click Matrix set EXE in file path to run software refer to following picture switcher...