4. Technical specification. 

 

  S-IP and S-MP pumps are assembled with a 3-phased motor. Version 2-pol or 4-pol. 

  50 or 60 Hz after choice. See motor label for accurate motor information on your pump. 

  230/400 or 400/690 after choice. See motor label for accurate motor information on your pump.  

  Motor space heater* 1x230vac. 50watt to 100watt. Have to be protected with an extern fuse. 

  Svend Höyer electric motors are type approved by BV, GL and ABS (design approval). 

  Svend Höyer electric motors are CE marked according to the Low Voltage Directive 2006/95/EC. 

  PTC resistance*:  200-250ohm at 20ºC.  (U = 7,5V max).  

  Thermistor. On/off. 135ºc. 

  Ambient temperature: up to max. 40ºC.  

  Media temperature: 5ºC to 100ºC 

  Flange according EN1092-1 

  Pump is based on design according ISO 2858. 

  Pump Standard surface treatment: Blue RAL 5010. C5M.  

 

*

 Only if it is built-in into the motor. 

 

 

 

 

Motor protection. 

 

Degree of protection is standard IP55, and insulation class is F. Tested to standard IEC 60034-2-1.  

The IE2 class motor has standard tropical windings.  

The IE3 class motor has tropical windings as an option.  

   

 

 

 

Pump material

 

 

    

Pump materiale as standard. 

Items 

S-IP 

S-MP 

Motor < 4 kw. 

Alu. 

Alu. 

Motor > 4 kw. 

Cast Iron 

Cast Iron 

Motor bracket 

Cast Iron 

Cast Iron 

Back plate 

Cast Iron 

Bronze RG10 

Mech Seal 

SiC/C-NITRIL 

SiC/C-NITRIL 

Pump shaft 

AISI 329 

AISI 329 

Impeller 

Bronze Ni.AL. 

Bronze Ni.AL. 

O-Ring 

Nitrile / NBR. 

Nitrile / NBR. 

Volute 

Cast Iron 

Bronze RG10 

Wear rings 

Bronze Ni.AL. 

Bronze Ni.AL. 

For some pump size can impeller i Stainless steel be an option  

 

 

 

 

 

Danpumps Pumps can be manufactured with other types of Mech. Seal and O-rings for specific conditions.

 

 

 

 

 

 

 

 

 

Содержание S-IP

Страница 1: ...In Line Pumps models S IP S MP End of life pump has to be recycled in accordance with local regulations Version 1 0 2017 ...

Страница 2: ...ter saltwater and water with small contaminants Impeller is a closed model S IP and S MP pumps are as standard assembled with Svend Hoyer electro motor Option S IP and S MP pumps can be ordered with other motor brands like ABB or BEVI Option Frequency Converter Drive direct mounted on the motor Option ATEX motor A22 II 3D Ex tc IIIB T120 ExnA II 3G Ex nA IIC T3 Option Forced Fan Cooling Option Bea...

Страница 3: ...EN1092 1 Pump is based on design according ISO 2858 Pump Standard surface treatment Blue RAL 5010 C5M Only if it is built in into the motor Motor protection Degree of protection is standard IP55 and insulation class is F Tested to standard IEC 60034 2 1 The IE2 class motor has standard tropical windings The IE3 class motor has tropical windings as an option Pump material Pump materiale as standard...

Страница 4: ...Pump dimensions ...

Страница 5: ... piping into place by tightening the flange bolts Pipes should be supported near the pump Never run the pump with suction side and discharge side blocked simultaneously Only shunt the pump on the discharge side Cavitation in the pump volute may occur if the pump s suction becomes obstructed Cavitation can cause damage to the internal elements of the pump especially on the impeller Always provide t...

Страница 6: ...ched off and cannot be switched on again accidental This also applies to the auxiliary power circuits e g anti condense heaters Check that supply voltage and frequency are the same as rated data Motors can be used with a supply deviation of 5 voltage and 2 frequency according to IEC60034 1 Connection diagrams for main supply and accessory as PTC or heater are located inside the terminal box Connec...

Страница 7: ...6 months and during possible extreme operating conditions more often For complete overhaul of the pump contact an authorized pumps workshop or your local DanPumps dealer Clean the pump carefully before dismantling it Follow local and national safety instructions Bearings in our DanPumps are lubricated for lift and don t need re lubrication Typical duty hours for motor with lifetime lubricated bear...

Страница 8: ...correct for the pump Water level in the well is too low open tank Impeller is partially clogged Pump vibrates Wear ring is worn Air inside pump house or periodically sucked into the pump The impeller is clogged Excessively high suction lift Seal not correct for the medie Pump has been running dry Pump is not running the right way The pump back pressure is too low The pump is missing 1 phase in the...

Страница 9: ...tions which give the pump a unique composition In order to find the correct spare parts for the pump then always inform about the pump serial number You will find the serial number on the DanPumps wet end label See page 2 Model pump with plug in shaft Model Pump with claw clutch 2L ...

Страница 10: ......

Страница 11: ......

Страница 12: ...12 CE Declaration ...

Страница 13: ...Nordager 25 DK 6000 Kolding Denmark Tel 45 86 571 344 www sonflow dk ...

Отзывы: