4
8.
Connecting to TP, Fiber Device
Converter
TP Port
10/100TP
AUTO, FORCE selectable: Bit 1, 2, & 3 of S1
a.
AUTO: 10/100 N-Way auto-negotiation
b.
FORCE: 100 or 10, FDX or HDX
Converter
Fiber Port
100FX
100Mbps duplex selectable: Bit 5 of S1
a.
FDX for 100FDX fiber link partner, default
b.
HDX for 100HDX fiber link partner
Fig. 11 S1-Bit 1, 2, 3, 4, & 5 Configuration and Setting
S1-1
TP port mode
: AUTO (Default) or FORCE
S1-2
TP port speed
: 100 (Default) or 10 when TP at FORCE
S1-3
TP port duplex
: FDX (Default) or HDX when TP at FORCE
S1-4
LFP
: LFP enabled (Default) or disabled
S1-5
Fiber port duplex
: 100FDX (Default) or 100HDX
Note: S1-2 and S1-3 will take effect only when S1-1 is set at TP-FORCE.
Warning:
—
When TP N-Way port is connected to TP 100FDX (FORCE mode) instead N-Way
partner, it will result in 100HDX mode with invalid collision signal
—
Ensure that all network nodes are configured at an identical operation mode.
Improper operation and flow control modes between TP and fiber port
connections will render the LAN at work poorly
9.
Cable Connection Parameter
100Base-X network allows 512-bit time delay between any two node-stations in a
collision domain. Switch-based Media Converter breaks up TP and fiber segments’
collision domain to extend the cabling distance.
•
TP Cables Limitations: Category 5 or better, up to 100m
•
Converter Fiber Cable Limitations:
SC/ST Converter Models
Multi-Mode Half-Duplex
412m
Multi-Mode Full-Duplex
2 km
Single-Mode Half-Duplex
412m
Single-Mode Full-Duplex
20/40/60km
•
Self Powering USB Cable Limitations: Type B to Type A USB cable, up to
5m
Warning
a.
When Self Powering cable is being used, be sure that the USB port is operational
b.
If connects to a PC/Notebook computer, the USB port driver need not be loaded
in order for the converter to draw power from cable provide that (a) is valid
c.
Battery consumption will be higher than usual if use notebook on battery
10.
TP-Fiber Technical Specifications
•
Standards: IEEE 802.3u 10/100Base-TX, 100Base-FX
•
Models:
Model
Connector
CFM3400C
1310nm Multi-Mode Duplex-SC
CFM3400T
1310nm Multi-Mode Duplex-ST
CFM3400C20
1310nm Single-Mode Duplex-SC 20km
CFM3400C40
1310nm Single-Mode Duplex-SC 40km
CFM3400C60
1310nm Single-Mode Duplex-SC 60km
•
Cable/Max Distance:
UTP
Category 5, up to 100m
Multi-Mode Fiber
50/125, 62.5/125, or 100/140µm, up to 2km
Single-Mode Fiber
8.3/125, 8.7/125, 9/125, or 10/125µm, up to 20~60km
•
LED Indicators: POWER, TP LNK/ACT, 100, FX LNK/ACT, FDX/COL
•
Data Transfer Rate:
Speed
Forwarding Rate
100Mbps
148,800
PPS
10Mbps
14,880 PPS
•
Flow Control:
IEEE 802.3x compliant for full-duplex, and
Back-Pressure flow control for half-duplex
•
Power Requirement:
1A@+5V DC from AC-DC Adapter
0.5A@+5V DC from USB Port
•
Ambient Temperature: 0° to 50° C
•
Humidity: 5% to 90%
•
Dimensions: 26.2 x 70.3 x 94 mm (H x W x D)
•