9
STEP 3
( Mounting the Hydraulic Power Unit )
1. After installing the Cart Wheels, attach the Power Unit
and Rubber Power Unit Dampener Pad to the Power Unit
Cart using the four 5/16”-18 x 3/4” Hex Bolts, Nuts and
Washers supplied. (See Fig 3.1)
2. Attach the Hydraulic Flow Divider to the Power Unit
Cart Using the four 5/16”-18 x 3/4” Hex Bolts, Nuts and
Washers supplied. (See Fig. 3.2)
3. Remove the three plastic plugs from the Flow Divider.
Install the 90-Degree Long 3/8” NPT Fitting and the 3/8” x
3/8” NPT Fittings to the Flow Divider as shown below. Use
Teflon tape on pipe threads only. (See Fig 3.3)
Note: For single column operation Hydraulic Hose connec-
tions see Page 21.
4. Thread the Male Quick Disconnect Fittings onto the
Fittings using Teflon tap on the pipe threads. (See Fig.
3.4)
5. Remove the plastic plug from the Power Unit. Install the
Long 90-Degree 3/8” x 3/8” O-Ring Fitting as shown below.
(See Fig 3.5)
6. Attach the Short Power Unit Hydraulic Hose as shown.
Do not use Teflon tape on the JIC Fittings. (See Fig. 3.6)
Fig 3.2
Fig 3.1.
Fig 3.3
Fig 3.5
Fig 3.6
Fig 3.4