Installation procedure

1.  Please read these notes carefully before commencing work. 

In case of doubt please consult a qualified electrician. 

Make sure the power is isolated from the circuit. 

If a four lug metal back box is being used the top and bottom lugs 

must be removed.

2.  The TLSW 10 (ILM) has two terminal blocks on the reverse, which 

should be connected as:

  Block 1 

L  

Live input 

  

SL  

Switched Line output

  Block 2 

Push Button   For connection to slave switch(es).† 

  

 

Must not be connected to the mains. 

3.  Existing two-way strapper lines can usually be used to connect 

these time lag switches in parallel or to connect slave switch(es), 

as shown in the wiring diagrams opposite.

4   When these devices are wired in parallel, dependant on the load, 

it may not be possible to immediately re-trigger the time lag.

5. The time lag is adjusted via a spindle (see 

illustration opposite) by inserting a narrow 

(flat) screwdriver through the hole located on 

the bottom edge of the device:

Notes:

When wiring has been completed and verified, switch on supply, wait 

for 30 seconds* and then test operation. 

* If this is not observed, see trouble shooting section for remedy.
† The two terminals on DANLERS slave switches are labelled as:
 

Plated Slave switches:  

Push Button 

 

Grid Slave switches:  

L, S

If grid slave switches are used with plated time lag switches, the 

L and S terminals must be connected only to the Push Button 

terminals on the time lag switch, not to live.

Typical wiring diagrams

 1-way TLSW 10 (ILM)

load

L

N

230 VAC

SL

Push

Button

Optional CAPLOAD,
Power factor
correction capacitor.
See minimum load.

L

TLSW 10 (ILM)

TIME

1

min

10

mins

APPROXIMATE

SETTINGS

5 mins

Example of a typical 2-way circuit

load

L

N

230 VAC

Multi-way TLSW 10 (ILM) with slave switches

L

N

230 VAC

load

SL

L

Push button

Slave

Switch

Slave

Switch

TLSW 10 

(ILM)

Unused existing wire

terminate safely

Push button

SS 1SL

SS 1SL

Optional CAPLOAD

See minimum load

Multi-way TLSW 10 (ILM) in parallel

L

N

230 VAC

load

SL

L

L

SL

SL

L

Unused existing wire
terminate safely

Push button

Push button

Push button

Optional CAPLOAD(s)

See minimum load

TLSW 10 

(ILM)

TLSW 10 

(ILM)

TLSW 10 