P
I
02 9604 1226 E
I
|
danielaappliances.com.au
PA G E 1 5
•
Using a flat bladed screwdriver remove the five screws, one in each corner of the hotplates
left and right spillage bowls and one centrally located at the rear of the centre spillage bowl.
•
Then lift the hob upwards. Replacement is a reversal of the above procedure.
•
Care must be taken to ensure that no damage occurs to the spark ignition leads or the
igniters. The electronic ignition pack is easily accessible for service or replacement below
the hob centrally at the rear.
GAS CONTROLS AND GAS MANIFOLD
•
Removal of the gas manifold is initially accomplished by removing the control knobs, the
trivets, the burner caps and burner head assemblies and skirts.
•
Using a flat bladed screwdriver remove the five screws, one in each corner of the hotplates
left and right spillage bowls and one centrally located at the rear of the centre spillage bowl.
•
Care must be taken to ensure that no damage occurs to the spark ignition leads, igniters
or thermocouples, if fitted. Disconnect all ancillary gas piping. Remove the two securing
brackets at the front and also the securing bracket near the gas inlet point to the burner
compartment. The gas manifold may then be extracted.
•
Replacement is reversal of the above procedure.
CONVERSION TO ANOTHER GAS TYPE
•
If the gas appliance is to be used with another gas type e.g. either Propane Gas or Natural
Gas, it must be converted by an Authorised Person.
•
Contact Daniela Appliances Pty Ltd or their authorised agent for information and parts.
NATURAL GAS
PROPANE GAS
Injector
Diameter
MJ/h
Gas
Pressure
Injector
Diameter
MJ/h
Gas
Pressure
Wok Burner
1.70
13
1.0 kPa
0.98
13
2.75 kPa
Large Burner
1.40
10
1.0 kPa
0.90
10.5
2.75 kPa
Medium Burner 1.10
6.5
1.0 kPa
0.70
6.5
2.75 kPa
Small Burner
0.90
4.2
1.0 kPa
0.55
3.7
2.75 kPa
***64
30.2 MJ/h
29.7 MJ/h
***75, ***95
40.2 MJ/h
40.2 MJ/h
The table above shows the appropriate injector sizes for either Natural Gas or LPG (Propane)