Danger MFS12TS Скачать руководство пользователя страница 5

Component Testing Procedures 

 

!

WARNING

 

To avoid risk of electrical shock, personal injury or death, disconnect power to oven and discharge capacitor  
before servicing, unless testing requires it. 

 

October 2013 

 

16500023 

©2013 ACP, Inc. 

 

5

 

All Amana and Menumaster microwave oven power outputs are rated using the IEC705 standards. Using the IEC705 
test method requires precision measurements and equipment that is not practical to be performed in the field. Using 
the test shown below will indicate if the oven performance is satisfactory. 

 

Test equipment required: 

 

1000 ml test container and thermometer. 

 

Digital watch / watch with a second hand for use on ovens with electromechanical timers. 

Important Notes: 

 

Low line voltage will cause low temperature rise / power output. 

 

Ovens must be on a dedicated circuit, properly grounded, and polarized. Other equipment on the same 
circuit may cause a low temperature rise / power output. 

 

This test and results are not a true IEC705 test procedures and are only intended to provide servicers with 
an easy means of determining if the microwave oven cooking output is correct. 

Procedure 

1.  Fill the test container to the 1000 ml line with cool tap water. 

NOTE:

 

Water temperature should be approximately 60

°

F / 16

°

2.  Using the thermometer, stir water for five to ten seconds; measure, and record the temperature (T1). 
3.  Place test container of water in the center of oven cavity and close door. 
4.  Heat the water for a 33-second full power cycle. 

NOTE:

 

Use a digital watch or a watch with a second hand for ovens with electromechanical timers. 

5.  At end of the cycle, remove test container. Using the thermometer, stir water for five to ten seconds and record 

temperature (T2). 

6.  Subtract the starting water temperature (T1), from the ending water temperature (T2) to obtain the temperature 

rise (

T). 

7.  If the temperature rise (

T) meets or exceeds the minimum, the test is complete. If the temperature rise (

T) 

fails to meet the minimum temperature rise, test the line voltage to verify it is correct. Then repeat steps 1 - 6 
making sure to change the water. If the temperature rise (

T) fails to meet the minimum temperature rise again 

the oven will require service. 

Minimum Temperature Rise at Thirty -Three (33) Seconds Run Time 

Cooking 

Cooking 

Cooking 

Cooking 

(°F) 

Power Output 

(°F) 

Power Output  

(°C) 

Power Output 

(°C) 

Power Output 

10.................. 1000 

20 ................. 2000 

5  ............... 1000 

11 ............ 2000 

11.................. 1100 

21 ................. 2100 

5.5 ............. 1100 

11.5 ......... 2100 

12.................. 1200 

22 ................. 2200 

6.5 ............. 1200 

12 ............ 2200 

14.................. 1400 

24 ................. 2400 

7.5 ............. 1400 

13 ............ 2400 

17.................. 1700 

25 ................. 2500 

9.5 ............. 1700 

13.5 ......... 2500 

18.................. 1800 

27 ................. 2700 

10 .............. 1800 

15 ............ 2700 

19.................. 1900 

30 ................. 3000 

10.5 ........... 1900 

16.5 ......... 3000 

 

 

Отзывы: