background image

28

To change  between °C and °F scaling

Press 

V

 and - together to toggle between °C and °F temperature 

scaling. 

Thermostat mode (Heating mode only)

a)  A constant temperature of between 5-30°C can be selected if 

required. This can provide frost protection for periods away from 
home, it can also be used to provide untimed higher temperatures 
if, for example, a family member is sick.

b) Press 

Λ

 

and 

V

 together to enter thermostat mode. The default 

setting is 5°C, but this can be reprogrammed, see 

User Advanced 

Programming

, step 10, (page 34).

c) A frost protection symbol (snowfl ake in a 

shield) will appear in the display when the 
selected temperature is equal to or less than the 
programmed frost protection setting.

d) Use the 

Λ

 

or 

V

 buttons to change the temperature away from the 

programmed frost protection temperature to another value.

e)  To return to automatic programming press both 

Λ

 and 

V

 together.

f )  Alternately, Thermostat mode can be accessed via the 

MODE

 

button (see page 31)

Changing the clock forwards and backwards

This is handled automatically, however, if the manual changeover has 
been selected (User Advanced Programming step 3 on page 34) follow 
the instructions below.

To change from Summer to Winter  (clocks back)

With clock display showing, press and hold 

-

 button until time moves 

back.

To change from Winter to summer (clocks forward)

With clock display showing, press and hold 

+

 button until time moves 

forward.

U

ser Instruc

tions

GB

Содержание TP9000

Страница 1: ...TP9000 Installation Instructions User Instructions Electronic Programmable Room Thermostat plus Domestic Hot Water Timer GB...

Страница 2: ...ller Advanced Programming Options 8 User Instructions 15 31 What is a Programmable Room Thermostat 15 Preset programmes 17 Setting Date and Time 18 Changing Preset Programmes 20 User overrides 27 User...

Страница 3: ...g 230 Vac 3 1 A 24Vac 3 1 A Memory Backup Retained for life of product Heat Temperature Range Setting 5 C 30 C Factory Set Calendar Clock Automatic Summer Winter time change Remote Sensor Inputs A mod...

Страница 4: ...ot on plug on module prior to mounting For wiring connections refer to diagram on page 6 The TP9000 is double insulated and does not require an earth connection however a parking terminal is provided...

Страница 5: ...ampfuse Itisstronglyrecommendedthatsolidconductorsbeused Clearance for screwdriver access Surface fixed cable bottom entry knockouts Rear entry cable access N looping terminals Wall or Plaster box fit...

Страница 6: ...ngth should not exceed 50 metres Sensor cable should NOT be run parallel to mains cable Remote sensor inputs The TP9000 incorporates an input which can be used to connect one of the following 1 remote...

Страница 7: ...ide of the wallplate 5 6 Window or teleswitch contact NO or NC 5 6 Teleswitch contact NC Window contact NC 5 6 Configured for remote room limit or outdoor sensor Configured for window contact or other...

Страница 8: ...ionality of the product These are accessed via an Installer Advanced Programming Mode These settings are optional and need only be made if there is a demand for the enhanced functions Service Interval...

Страница 9: ...ion 31 Set lower limit of temperature range This allows the lower limit of the thermostat setting range to be electronically limited Press until Option 31 is displayed use V and to select required set...

Страница 10: ...of the PI algorithm to increase control accuracy It is only active if option 34 has been set to Chrono 3 6 9 or 12 It should only be adjusted after seeking advice from the manufacturer Press until Opt...

Страница 11: ...at mode 2 Two switching events per day 4 Four switching events per day 6 Six switching events per day factory setting Option 41 Operating Mode Heating option 40 set to 2 4 or 6 This sets the thermosta...

Страница 12: ...Setting 0 Normal lock Programming functions locked factory setting Setting 1 Full lock All keys are disabled Option 71 Random start rules 24V 230 Volt models only This enables a random start on power...

Страница 13: ...0 European format dd mm yy Factory setting Setting 1 North American format mm dd yy Option 80 Enable Disable Hrs Boost Enables or disables the Hrs button use V and to select required setting Press unt...

Страница 14: ...typical application is floor Heating Press until Option 93 is displayed use V and to select required setting If the temperature sensed by the limit sensor exceeds the limit setting the output will be...

Страница 15: ...mfortable with at the different times you have chosen and then leave it alone to do its job The best way to do this is to set low temperatures first say 18 C and then turn them up by one degree each d...

Страница 16: ...on The Heating side of the TP9000 can be set by your installer to provide up to 2 4 or 6 time and temperature settings each day whereas the Hot Water can be set to provide 1 2 or 3 on off periods each...

Страница 17: ...urrent output status on off The output status is always shown for both Heating and Hot Water regardless of the display mode Preset programmes YourTP9000 comes ready programmed with a set of operating...

Страница 18: ...P9000 incorporates a real time clock with calendar function that automatically changes time in both Spring and Autumn The time and date is set in the factory for the UK time zone and does not normally...

Страница 19: ...month If you attempt to select an invalid date the unit software will reject it and apply the nearest valid date It is recommended that date is set in the order yy mm dd Setting the correct time Afte...

Страница 20: ...plied to different days of the week If this is required refer to page 23 for instructions on how to turn on this feature Please Note The unit must be programmed in sequence event times cannot be set o...

Страница 21: ...ss DAY HOL to move to the next day f Repeat steps b c d e to programme the remaining weeks events g Press and hold PROG to return to the main screen Changing the preset programmes in 5 2 day mode For...

Страница 22: ...Changing the preset programmes in 24 hour mode a Press PROG until the first preset time and temperature Event 1 for all days of the week appears in display b Use the and buttons to adjust the TIME pr...

Страница 23: ...TUE WED THU FRI Use the and keys to scroll forwards or backwards through the days of the week To deselect a day press V for example TUE To select a day press for example SUN Any deselected days are a...

Страница 24: ...Repeat steps b c d to programme the remaining events Running the programme Press PROG to return to previous RUN mode The Heating will now follow the times and temperatures programmed Copy functions e...

Страница 25: ...back to the flashing day and press the COPY button The previously flashing day will stop flashing to indicate it has been de selected Holiday programme The TP9000 is equipped with a holiday mode that...

Страница 26: ...heating and hot water can be set Use the CH HW button to change betweenheating and hot water display mode g The Heating set temperature for the duration of the holiday mode can be adjusted by selecti...

Страница 27: ...This override will automatically be cancelled at the beginning of the next programmed event Please note that your installer may have restricted the duration of the override to something other than nex...

Страница 28: ...e selected temperature is equal to or less than the programmed frost protection setting d Use the or V buttons to change the temperature away from the programmed frost protection temperature to anothe...

Страница 29: ...t of an event is close to the programmed value If you have enabled this function it can be overridden by pressing either or V buttons To enable this feature please refer to User Advanced Programming s...

Страница 30: ...will cause the Hot Waterto remain on for an extra 1 2 or 3 hours if already on or will switch the water on for 1 2 or 3 hours if currently off BOOST 1 2 or 3 HRS will be shown in the display For Heati...

Страница 31: ...ith 6 events per day for heat or 3 for Hot Water ON Indicates Hot Water is permanently on Applies to Hot Water only OFF Indicates permanently off for Hot Water or Thermostat mode see page 28 for Heati...

Страница 32: ...tdoor temperature followed by the lowest and highest outdoor temperatures in the last 24 hours If Service Due date is set Pressing the INFO button will display the date the service is due If in holida...

Страница 33: ...nd V keys to change option settings The flashing digit on the right hand of the display indicates the number of the selected option Option 1 Enable or disable A B programming Option 41 and or 61 set t...

Страница 34: ...and corrects time display Press until Option 4 is displayed use and V to select required setting Setting 0 UK models this feature should be left at the factory setting of 0 Setting 1 Central European...

Страница 35: ...Heating is turned up This will vary with weather conditions ranging from a maximum of 120 minutes to 0 minutes before the programmed event time This setting must be used together with option 12 to ma...

Страница 36: ...ng 0 45 45 mins warm air system poorly insulated building 1 00 60 mins radiator system light weight well insulated building Factory setting 1 15 75 mins radiator system light weight medium insulation...

Страница 37: ...lower temperature that you are able to set on the thermostat Temperature override limitation This allows the installer to limit the number of degrees that you can override the programmed temperature...

Страница 38: ...l overrides and programming buttons will be disabled and the Heating and Hot Water may operate for a limited amount of time each hour The installer may cancel or reset the service interval timer as pa...

Страница 39: ...Option 70 Keyboard disable rules Option 71 Random start rules Option 72 Owner site reference number Option 73 Owner thermostat reference number Option 74 Date format for calendar clock Option 80 Enabl...

Страница 40: ...40 www danfoss com BusinessAreas Heating Part No 62052v01s1 00 03 08...

Отзывы: