Table 86: Brake resistor maximum power limit (0x7181 / 0x142)
Code
PROFINET
®
code
Name
Severity (warning/
error/trip lock)
Description
LCP name
0x7181
0x142
Brake resistor maxi-
mum power limit
Warning, error
The brake resistor maximum
power limit is exceeded.
brake pwr
lim
9.3.52 Brake resistor user power limit (0x7182 / 0x143)
This error is valid for PSM 510.
Table 87: Brake resistor user power limit (0x7182 / 0x143)
Code
PROFI‐
NET
®
code
Name
Severity
(warning/
error/trip
lock)
Description
LCP
name
0x7182
0x143
Brake resis-
tor user
power limit
Warning, er-
ror
The brake resistor power limit is exceeded.
The power transmitted to the brake resistor is calculated as an
average value over the last 300 s of run time.
-The calculation is based on the DC-link voltage and the brake
resistor value set in parameter
2-16
(Brake resistor power 300 s).
The error is reported when the value is exceeded within 300 s.
brake usr
pwr lim
9.3.53 Brake mains voltage too high (0x7183 / 0x159)
This error is valid for PSM 510.
Table 88: Brake mains voltage too high (0x7183 / 0x159)
Code
PROFINET
®
code
Name
Severity (warning/error/
trip lock)
Description
LCP name
0x7183
0x159
Brake mains volt-
age too high
Warning
The brake resistor mains volt-
age is too high.
brake volt
high
9.3.54 Internal position sensor error (0x7320 / 0x10C)
This error is valid for SDM 511/SDM 512.
Table 89: Internal position sensor error (0x7320 / 0x10C)
Code
PROFINET
®
code
Name
Severity (warning/
error/trip lock)
Description
LCP name
0x7320
0x10C
Internal position sensor
error
Trip lock
Absolute position sensor er-
ror.
int sensor err
Diagnostics
Operating Guide | VLT® Multiaxis Servo Drive MSD 510 System
AQ262450196490en-000101 / 175R1170
184 | Danfoss A/S © 2019.10
Содержание VLT MSD 510