Analog Inputs:
Number of analog inputs

2

Terminal number

53, 60

Voltage mode (Terminal 53)

Switch S200=OFF(U)

Current mode (Terminal 53 and 60)

Switch S200=ON(I)

Voltage level

0 -10V

Input resistance, R

i

approx. 10 kΩ

Max. voltage

20V

Current level

0/4 to 20 mA (scaleable)

Input resistance, R

i

approx. 200Ω

Max. current

30mA

Analog output:
Number of programmable analog outputs

1

Terminal number

42

Current range at analog output

0/4 - 20mA

Max. load to common at analog output

500Ω

Max. voltage at analog output

17V

Accuracy on analog output

Max. error: 0.8 % of full scale

Resolution on analog output

8bit

Control card, RS-485 serial communication:
Terminal number

68 (P,TX+, RX+), 69 (N,TX-, RX-)

Terminal number 61

Common for terminals 68 and 69

Control card, 24 V DC output:
Terminal number

12

Max. load (M1 and M2)

160mA

Max. load (M3)

30mA

Max. load (M4 and M5)

200mA

Relay output:
Programmable relay output

1

Relay 01 Terminal number

01-03 (break), 01-02(make)

Max. terminal load (AC-1)

1)

 on 01-02 (NO) (Resistive load)

250V AC, 2 A

Max. terminal load (AC-15)

1)

 on 01-02 (NO) (Inductive load @ cosφ 0.4)

250V AC, 0.2 A

Max. terminal load (DC-1)

1)

 on 01-02 (NO) (Resistive load)

30V DC, 2 A

Max. terminal load (DC-13)

1)

 on 01-02 (NO) (Inductive load)

24V DC, 0.1A

Max. terminal load (AC-1)

1)

 on 01-03 (NC) (Resistive load)

250V AC, 2 A

Max. terminal load (AC-15)

1)

 on 01-03 (NC) (Inductive load @ cosφ 0.4)

250V AC, 0.2A

Max. terminal load (DC-1)

1)

 on 01-03 (NC) (Resistive load)

30V DC, 2 A

Min. terminal load on 01-03 (NC), 01-02 (NO)

24V DC 10 mA, 24V AC 20 mA

Environment according to EN 60664-1

overvoltage category III/pollution degree 2

1) IEC 60947 part 4 and 5

Control card, 10 V DC output:
Terminal number

50

Output voltage

10.5V ±0.5V

Max. load

25mA

NOTE

All inputs, outputs, circuits, DC supplies and relay contacts
are galvanically isolated from the supply voltage (PELV)
and other high-voltage terminals.

Quick Guide

VLT Micro Drive Quick Guide

MG.02.B6.02 - VLT

®

 is a registered Danfoss trademark

17

1

1

Содержание VLT Micro Drive

Страница 1: ...MAKING MODERN LIVING POSSIBLE Quick Guide VLT Micro Drive...

Страница 2: ...equency switching at high power This will generate a leakage current in the earth connection A fault current in the frequency converter at the output power terminals might contain a DC component which...

Страница 3: ...e the frequency converter is connected to mains the motor can be started stopped using digital commands bus commands references or via the LCP Disconnect the frequency converter from mains whenever pe...

Страница 4: ...248 9 5 1 For LCP with potentiometer please add 7 6mm Table 1 1 Mechanical Dimensions 1 3 4 Electrical Installation in General NOTE All cabling must comply with national and local regulations on cable...

Страница 5: ...FC 51 Max Fuses UL Max fuses non UL Bussmann Bussmann Bussmann Littel fuse Ferraz Shawmut Ferraz Shawmut 1 X 200 240V kW Type RK1 Type J Type T Type RK1 Type CC Type RK1 Type gG 0K18 0K37 KTN R15 JKS...

Страница 6: ...and W Step 3 Mount mains supply to terminals L1 L L2 and L3 N 3 phase or L1 L and L3 N single phase and tighten Illustration 1 2 Mounting of Earth Cable Mains and Motor Wires 1 3 7 Control Terminals...

Страница 7: ...lying Start term 18 and an analog reference term 53 or 60 make the frequency converter run Illustration 1 5 Overview of Control Terminals in PNP configuration and Factory Setting Quick Guide VLT Micro...

Страница 8: ...3 9 Load sharing Brake Use 6 3 mm insulated Faston Plugs designed for high voltage for DC Load Sharing and brake Contact Danfoss or see instruction no MI 50 Nx 02 for load sharing and instruction no...

Страница 9: ...C via RS485 com port by installing the MCT 10 Set up Software This software can either be ordered using code number 130B1000 or downloaded from the Danfoss Web site www danfoss com BusinessAreas Drive...

Страница 10: ...above the operation keys indicates the active key Hand on Starts the motor and enables control of the frequency converter via the LCP Off Reset Stops the motor off If in alarm mode the alarm will be r...

Страница 11: ...oast delay time 1 73 Flying Start 0 Disabled 1 Enabled 1 8X Stop Adjustments 1 80 Function at Stop 0 Coast 1 DC hold 1 82 Min Speed for Funct at Stop Hz 0 0 20 0 Hz 0 0 Hz 1 9XMotor Temperature 1 90 M...

Страница 12: ...minal 60 Filter Time Constant 0 01 10 00s 0 01s 6 8X LCP potentiometer 6 80 LCP Potmeter Enable 0 Disabled 1 Enable 6 81 LCP potm Low Reference 4999 4999 0 000 6 82 LCP potm High Reference 4999 4999 5...

Страница 13: ...4 01 Switching Frequency 0 2 kHz 1 4 kHz 2 8 kHz 4 16 kHz not available for M5 14 03 Overmodulation 0 Off 1 On 14 1X Mains monitoring 14 12 Function at mains imbalance 0 Trip 1 Warning 2 Disabled 14 2...

Страница 14: ...h fault X X Discharge from output phases to ground 47 Control Voltage Fault X X 24 V DC may be overloaded 51 AMT check Unom and Inom X Wrong setting for motor voltage and or motor current 52 AMT low I...

Страница 15: ...C 1 At rated load conditions 1 7 2 Mains Supply 3 x 200 240V AC Normal overload 150 for 1 minute Frequency converter Typical Shaft Output kW PK25 0 25 PK37 0 37 PK75 0 75 P1K5 1 5 P2K2 2 2 P3K7 3 7 Ty...

Страница 16: ...Supply 3 x 380 480V AC 1 At rated load conditions Normal overload 150 for 1 minute Frequency converter Typical Shaft Output kW P5K5 5 5 P7K5 7 5 P11K 11 P15K 15 P18K 18 5 P22K 22 Typical Shaft Output...

Страница 17: ...ing not more than 100 000 RMS symmetrical Amperes 240 480V maximum Motor output U V W Output voltage 0 100 of supply voltage Output frequency 0 200Hz VVC 0 400Hz u f Switching on output Unlimited Ramp...

Страница 18: ...mable relay output 1 Relay 01 Terminal number 01 03 break 01 02 make Max terminal load AC 1 1 on 01 02 NO Resistive load 250V AC 2 A Max terminal load AC 15 1 on 01 02 NO Inductive load cos 0 4 250V A...

Страница 19: ...C Minimum ambient temperature at reduced performance 10 C Temperature during storage transport 25 65 70 C Maximum altitude above sea level without derating 1000 m Maximum altitude above sea level with...

Страница 20: ...he motor is adequate A problem may occur at low speeds in constant torque applications Running continuously at low speeds below half the nominal motor speed may require additional air cooling Alternat...

Страница 21: ...www danfoss com drives MG02B602 132R0029 MG02B602 Rev 2011 08 03...

Отзывы: