5.3.25 Conversion of Parameter 226 Warning High Frequency
Table 86: Parameter 226
FCD 300 series
FCD 302 series
Parameter
226 Warning High Frequency
4-53 Warning Speed High
Range
Parameter 225
to
parameter 202
Parameter 4-52
to
parameter 4-13
5.3.26 Conversion of Parameter 227 Warning Low Feedback
Table 87: Parameter 227
FCD 300 series
FCD 302 series
Parameter
227 Warning Low Feedback
4-56 Warning Feedback Low
Range
-100000.000 to
parameter 228
-999999.999 to
parameter 4-57
5.3.27 Conversion of Parameter 228 Warning High Feedback
Table 88: Parameter 228
FCD 300 series
FCD 302 series
Parameter
228 Warning High Feedback
4-57 Warning Feedback High
Range
Parameter 227
to 1000000.000
Parameter 4-57
to 999999.999
5.3.28 Conversion of Parameter 229 Frequency Bypass, Bandwidth
Table 89: Parameter 229
FCD 300 series
FCD 302 series
Parameter
229 Frequency Bypass, Bandwidth
Stored in EEPROM only
Range
0–100%
–
5.3.29 Conversion of Parameter 230 Frequency Bypass 1
Table 90: Parameter 230
FCD 300 series
FCD 302 series
Parameter
230 Frequency Bypass 1
4-61 Bypass Speed From [Hz]
4-63 Bypass Speed To [Hz]
Range
0 to
parameter 200
0 to
parameter 4-14
Parameter Mapping Lists
Operating Guide | VLT® FCD 300 PROFIBUS Converter MCA 117
AQ289550754901en-000101 / 130R0890| 47