45 (60)
84
3
9
130B1291
130B1201
55 (74)
103
3
9
130B1292
130B1204
75 (100)
140
3
8
130B1294
130B1213
90 (120)
176
3
8
130B1294
130B1213
Table 28: AHF Filters (5% Current Distortion)
3x440–480 V 60 Hz
Power [kW (hp)] Drive input cur-
rent Continuous
[A]
Default switching
frequency [kHz]
THDi level [%] Order number filter
IP00
Code number filter
IP20
22 (30)
34.6
4
3
130B1792
130B1757
30 (40)
49
4
3
130B1793
130B1758
37 (50)
61
4
3
130B1794
130B1759
45 (60)
73
3
4
130B1795
130B1760
55 (74)
89
3
4
130B1796
130B1761
75 (100)
121
3
5
130B1797
130B1762
90 (120)
143
3
5
130B1798
130B1763
Table 29: AHF Filters (10% Current Distortion)
3x440–480 V 60 Hz
Power [kW (hp)] Drive input cur-
rent continuous
[A]
Default switching
frequency [kHz]
THDi level [%] Order number filter
IP00
Code number filter
IP20
22 (30)
34.6
4
6
130B1775
130B1487
30 (40)
49
4
8
130B1776
130B1488
37 (50)
61
4
7
130B1777
130B1491
45 (60)
73
3
9
130B1778
130B1492
55 (74)
89
3
8
130B1779
130B1493
75 (100)
121
3
9
130B1780
130B1494
90 (120)
143
3
10
130B1781
130B1495
4.3.3 External RFI Filter
With external filters listed in the following table, the maximum shielded cable length of 50 m (164 ft) according to EN/IEC 61800-3
C2 (EN 55011 A1), or 20 m (65.6 ft) according to EN/IEC 61800-3 C1(EN 55011 B) can be achieved.
Table 30: RFI Filters - Details
Power
[kW
(hp)]
Size
380–
480 V
Type
A
B
C
D
E
F
G
H I
J
K
L1 Torque
[Nm (in-
lb)]
Weight
[kg (lb)]
Ordering
Number
AJ363928382091en-000101 / 130R0983 | 51
Danfoss A/S © 2021.04
Selection and Ordering
VLT® Flow Drive FC 111
Design Guide