Procedure
1. Open the app and establish the Wi-Fi connection, see
for descriptions of the white Wi-Fi LED.
2. When prompted, change the default password due to security restrictions. The password must be at least 8 and maximum 48
characters.
3. Replug the VLT® Wireless Communication Panel LCP 103 for the password to take effect. Failing to do so, allows the LCP 103 to
keep broadcasting.
4. Disconnect the app, navigate to smart device settings, and forget the network.
5. Search for the wireless network and connect with the new password.
NOTICE
If the password is not changed, it leaves only 10 minutes for connecting and performing drive operations. After this, the
wireless connection closes.
If the wireless SSID and password are forgotten, reset the password by accessing
parameter group 30-9* Wifi LCP via MCT 10 Set-up
Software or LCP 102
.
2.3 LED Pattern
Table 1: Descriptions, LED Indicators
LED
Pattern
Description
On
Solid green
The drive is powered on (normal operation).
Wi-Fi
Flashing white
Connection pairing successful.
Solid white
The smart device is connected and communication is OK.
Alarm
Flashing red
An alarm has occurred.
Warn
Solid yellow
A warning has occurred.
MS, NS1, NS2
(1)
Flashing orange
Identification of the drive when initiated through a winking command
Flashing, then solid orange
Incompatible drive (LED flashes 3 times and then remains on).
1
MS=module status, NS1=network status, NS2=network status 2.
2.4 Safe Control
The safe control parameter allows the drive to decide the motor behavior if the smart device, for example a tablet, communication is
lost. If the limits are set to
[1] Stop motor
, the motor stops. If the limits are set to
[0] Do nothing
, the motor continues to run. This is only
applicable when the motor is in Run state and if the motor has been started from the app.
The communication happens between the MyDrive® Connect App and the VLT® Wireless Communication LCP 103.
Parameter
Limits/options
Parameter 30-97 Wifi Timeout Action
[0] Do nothing
[1] Stop motor
Installation
Installation Guide | VLT® Wireless Communication Panel LCP 103
AN331428064824en-000101 / 130R0814 | 7
Danfoss A/S © 2020.02