Decentral Solutions
Thermal load [%]
(FC. THERMAL[%])
[14]
Running hours [Hours]
(RUNNING HOURS])
[15]
Digital input [Bin]
(DIGITAL INPUT[BIN])
[16]
Analog input 53 [V]
(ANALOG INPUT 53 [V])
[17]
Analog input 60 [mA]
(ANALOG INPUT 60 [MA])
[19]
Pulse reference [Hz]
(PULSE INPUT 33. [HZ])
[20]
External reference [%]
(EXTERNAL REF. [%])
[21]
Status word [Hex] (STATUS WORD [HEX])
[22]
Heatsink temperature [°C]
(HEATSINK TEMP [°C])
[25]
Alarm word [Hex] (ALARM WORD [HEX])
[26]
Control word [Hex] (CONTROL WORD [HEX])
[27]
Warning word [Hex]
(WARNING WORD [HEX])
[28]
Extended status word [Hex]
(EXT. STATUS [HEX])
[29]
Communication option card warning
(COMM OPT WARN [HEX])
[30]
Pulse count
(PULSE COUNTER)
[31]
Pulse input 29
(PULSE INPUT 29)
[32]
Function:
In this parameter you can select the data value that
you wish to display in the LCP control unit display
line 2 when the variable frequency drive is switched
on. The display will also be included in the scrollbar
in display mode. In parameters 010-012
Display
readout
you can select a further three data values,
which are displayed in display line 1.
Description of choice:
No readout
can only be selected in parameters
010-012
Small display readout
.
Resulting reference [%]
gives, as a percentage,
the resulting reference in the range from Minimum
reference, Ref
MIN
to Maximum reference, Ref
MAX
.
Reference [unit]
gives the resulting reference with unit
Hz in
Open loop
. In
Closed loop
the reference unit
is selected in parameter 416
Process units
.
Feedback [unit]
gives the resulting signal value
using the unit/scaling selected in parameter 414
Minimum feedback, FB
LOW
, 415
Maximum feedback,
FB
HIGH
and 416
Process units
.
Frequency [Hz]
gives the output frequency of
the variable frequency drive.
Output frequency x scaling [-]
equals the present output
frequency f
M
multiplied by the factor set in parameter
008
Display scaling of output frequency
.
Motor current [A]
gives the phase current of the
motor measured as an effective value.
Torque [%]
denotes the motor
’
s present load in
relation to the motor
’
s rated torque.
Power [kW]
gives the present power that the
motor is absorbing in kW.
Power [HP]
gives the present power that the
motor is absorbing in HP.
Motor voltage[V]
gives the voltage supplied to the motor.
DC link voltage [V]
gives the intermediate circuit
voltage of the variable frequency drive.
Thermal load motor [%]
gives the calculated/estimated
load on the motor. 100 % is the cut-out limit.
Thermal load [%]
gives the calculated/estimated
thermal load on the variable frequency drive.
100 % is the cut-out limit.
Running hours [Hours]
gives the number of hours that
the motor has run since the last reset in parameter
619
Reset of running hours counter
.
Digital input [Binary code]
gives the signal status
from the 5 digital inputs (18, 19, 27, 29 and 33).
Terminal 18 corresponds to the bit on the extreme
left. ‘0
’
= no signal, ‘1
’
= signal connected.
Analog input 53 [V]
gives the voltage value of terminal 53.
Analog input 60 [mA]
gives the present value
of terminal 60.
Pulse input 33[Hz]
gives the frequency in Hz
connected to terminal 33.
✭
= factory setting. () = display text [] = value for use in communication via serial communication port
MG.90.F2.22 - VLT is a registered Danfoss trademark
102
Содержание VLT DMS 300
Страница 28: ...Decentral Solutions Ordering form FCD 300 MG 90 F2 22 VLT is a registered Danfoss trademark 28 ...
Страница 48: ...Decentral Solutions Electrical Schematic MG 90 F2 22 VLT is a registered Danfoss trademark 48 ...
Страница 178: ...Decentral Solutions Dimensions of mounting brackets MG 90 F2 22 VLT is a registered Danfoss trademark 178 ...