10-11 Process Data Config Write
Select the process write data for I/O assembly instances 101/151.
Elements [2] and [3] of this array can be selected. Elements [0]
and [1] of the array are fixed.
Option:
Function:
[303]
Maximum Reference
[312]
Catch up/slow Down Value
[341]
Ramp 1 Ramp Up Time
[342]
Ramp 1 Ramp Down Time
[351]
Ramp 2 Ramp Up Time
[352]
Ramp 2 Ramp Down Time
[380]
Jog Ramp Time
[381]
Quick Stop Ramp Time
[411]
Motor Speed Low Limit [RPM]
[412]
Motor Speed Low Limit [Hz]
[413]
Motor Speed High Limit [RPM]
[414]
Motor Speed High Limit [Hz]
[416]
Torque Limit Motor Mode
[417]
Torque Limit Generator Mode
[553]
Term. 29 High Ref./Feedb. Value
[558]
Term. 33 High Ref./Feedb. Value
[590]
Digital & Relay Bus Control
[593]
Pulse Out #27 Bus Control
[595]
Pulse Out #29 Bus Control
[597]
Pulse Out #X30/6 Bus Control
[615]
Terminal 53 High Ref./Feedb.
Value
[625]
Terminal 54 High Ref./Feedb.
Value
[653]
Term 42 Output Bus Ctrl
[663]
Terminal X30/8 Bus Control
[673]
Terminal X45/1 Bus Control
[683]
Terminal X45/3 Bus Control
[748]
PCD Feed Forward
[890]
Bus Jog 1 Speed
[891]
Bus Jog 2 Speed
[1680]
Fieldbus CTW 1
[1682]
Fieldbus REF 1
[1685]
FC Port CTW 1
[1686]
FC Port REF 1
10-12 Process Data Config Read
Select the process read data for I/O assembly instances 101/151.
Elements [2] and [3] of this array can be selected. Elements [0]
and [1] of the array are fixed.
Option:
Function:
[0]
None
[15]
Readout: actual setup
[1472]
Legacy Alarm Word
[1473]
Legacy Warning Word
[1474]
Leg. Ext. Status Word
[1500]
Operating hours
[1501]
Running Hours
[1502]
kWh Counter
10-12 Process Data Config Read
Select the process read data for I/O assembly instances 101/151.
Elements [2] and [3] of this array can be selected. Elements [0]
and [1] of the array are fixed.
Option:
Function:
[1600]
Control Word
[1601]
Reference [Unit]
[1602]
Reference %
[1603]
Status Word
[1605]
Main Actual Value [%]
[1606]
Absolute Position
[1609]
Custom Readout
[1610]
Power [kW]
[1611]
Power [hp]
[1612]
Motor Voltage
[1613]
Frequency
[1614]
Motor current
[1615]
Frequency [%]
[1616]
Torque [Nm]
[1617]
Speed [RPM]
[1618]
Motor Thermal
[1619]
KTY sensor temperature
[1620]
Motor Angle
[1621]
Torque [%] High Res.
[1622]
Torque [%]
[1623]
Motor Shaft Power [kW]
[1624]
Calibrated Stator Resistance
[1625]
Torque [Nm] High
[1630]
DC Link Voltage
[1632]
Brake Energy /s
[1633]
Brake Energy Average
[1634]
Heatsink Temp.
[1635]
Inverter Thermal
[1638]
SL Controller State
[1639]
Control Card Temp.
[1645]
Motor Phase U Current
[1646]
Motor Phase V Current
[1647]
Motor Phase W Current
[1648]
Speed Ref. After Ramp [RPM]
[1650]
External Reference
[1651]
Pulse Reference
[1652]
Feedback[Unit]
[1653]
Digi Pot Reference
[1657]
Feedback [RPM]
[1660]
Digital Input
[1661]
Terminal 53 Switch Setting
[1662]
Analog Input 53
[1663]
Terminal 54 Switch Setting
[1664]
Analog Input 54
[1665]
Analog Output 42 [mA]
[1666]
Digital Output [bin]
[1667]
Freq. Input #29 [Hz]
[1668]
Freq. Input #33 [Hz]
[1669]
Pulse Output #27 [Hz]
Parameters
Programming Guide
MG92F102
Danfoss A/S © 12/2015 All rights reserved.