Static test procedures
Step 4
Now reverse the meter leads, i.e. connect
the positive terminal of the meter lead to the
negative DC bus.
• Connect the negative terminal of the meter
lead to the motor terminals U, V, W in turn.
•
The multimeter should show diode drop
around 0.4 volts.
Figure 19: The multimeter
should show diode drop
around 0.4 volts