[CHANGE DATA] is used for changing the
parameter selected either in the Menu
mode or the Quick menu mode.
[CANCEL] is used if a change of the
selected parameter is not to be carried
out.
[OK] is used for confirming a change of
the parameter selected.
[+]/[-] is used for selecting parameter and
for changing the chosen parameter or for
changing the read out in line 2.
[<][>] is used for selecting group and to
move the cursor when changing
numerical parameters.
[STOP/RESET] is used for stopping or for
resetting the FC motor after a drop-out
(trip). Can be selected via parameter 014
to be active or inactive. If stop is
activated, line 2 will flash, and [START]
must be activated.
Table 3.2
NOTICE
Pressing [STOP/RESET] will prevent motor from running
also with disconnected LCP 2. Restarting is only possible
via the LCP 2 [START] key.
[JOG] overrides the output frequency to a
preset frequency while the key is kept
down. Can be selected via parameter 015
to be active or inactive.
[FWD/REV] changes the direction of
rotation of the motor, which is indicated
by means of the arrow on the display
although only in Local. Can be selected
via parameter 016 to be active or inactive
(parameter 013 must be set to [1] or [3]
and parameter 200 set to [1].
[START] is used for starting the FC motor
after stop via the [Stop] key. Is always
active, but cannot override a stop
command given via the terminal strip.
Table 3.3
NOTICE
If the keys for local control have been selected as active,
they will remain active both when the frequency has
been set for
Local Control
and for
Remote Control
via
parameter 002, although with the exception of [FWD/
REV], which is only active in Local operation.
NOTICE
If no external stop function has been selected and the
[STOP] key has been selected as inactive via parameter
014, the FC motor can be started and can only be
stopped by disconnecting the voltage to the motor.
3.1.8 Display Read-out State
The display read-out state can be varied - see
- depending on whether the FC
motor is in normal operation or is being programmed.
3.1.9 Display Mode
In normal operation, up to 4 different operating variables
can be indicated continuously: 1.1 and 1.2 and 1.3 and 2,
and in line 4 the present operating status or alarms and
warnings that have arisen.
195NA113.10
VAR 2
SETUP
1
STATUS
VAR 1.1 VAR 1.2 VAR 1.3
Illustration 3.7
3.1.10 Display Mode - Selection of Read-
out State
There are three options in connection with the choice of
read-out state in the Display mode - I, II and III. The choice
of read-out state determines the number of operating
variables read out.
Read-out
state:
I:
II:
III:
Line 1
Description for
operating
variable in line
2
Data value for
3 operating
variables in
line 1
Description for
3 operating
variables in
line 1
Table 3.4
gives the units linked to the variables in the first
and second line of the display (see parameter 009).
Programming
VLT
®
DriveMotor FCM Series
30
MG03BA02 - VLT
®
is a registered Danfoss trademark
3
3
Содержание VLT Brook Crompton Motor FCM 300
Страница 1: ...MAKING MODERN LIVING POSSIBLE Design Guide VLT Brook Crompton Motor FCM 300 www danfoss com drives...
Страница 2: ......
Страница 26: ...Illustration 2 5 Installation VLT DriveMotor FCM Series 24 MG03BA02 VLT is a registered Danfoss trademark 2 2...
Страница 37: ...Programming VLT DriveMotor FCM Series MG03BA02 VLT is a registered Danfoss trademark 35 3 3...
Страница 101: ...Index VLT DriveMotor FCM Series MG03BA02 VLT is a registered Danfoss trademark 99...
Страница 102: ...www danfoss com drives MG03BA02 175R0087 MG03BA02 Rev 2011 12 22...