7 How to Order
7.1 Drive Configurator
F C
-
P
T
130BB836.10
X
S
A
B
C
X
X X
X
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18 19 20
30
22
21
23
27
25
24
26
28 29
31
37
36
35
34
33
32
38 39
X
D
Illustration 7.1 Type Code Example
Configure the right frequency converter for the right
application from the Internet based Drive Configurator and
generate the type code string. The Drive Configurator
automatically generates an 8-digit sales number to be
delivered to the local sales office.
Furthermore, it is possible to establish a project list with
several products and send it to a Danfoss sales represen-
tative.
The Drive Configurator can be found on the global
Internet site: www.danfoss.com/drives.
7.1.1 Type Code
An example of the type code is:
FC-302PK75T5E20H1BGCXXXSXXXXA0BXCXXXXD0
The meaning of the characters in the string can be found
in
and
. In the example above, a Profibus
DP V1 and a 24 V back-up option is built-in.
Description Pos
Possible choices
Product group 1-3
FC 30x
Drive series
4-6
301: FC 301
302: FC 302
Power rating
8-10
0.25-75 kW
Phases
11
Three phases (T)
Mains voltage 11-
12
T2: 200-240 V
T4: 380-480 V
T5: 380-500 V
T6: 525-600 V
T7: 525-690 V
Enclosure
13-
15
E20: IP20
E55: IP 55/NEMA Type 12
P20: IP20 (with back plate)
P21: IP21/ NEMA Type 1 (with back
plate)
P55: IP55/ NEMA Type 12 (with back
plate)
Z20: IP 20
1)
E66: IP 66
Description Pos
Possible choices
RFI filter
16-
17
Hx: No EMC filters built in the frequency
converter (600 V units only)
H1: Integrated EMC filter. Fulfil EN
55011 Class A1/B and EN/IEC 61800-3
Category 1/2
H2: No additional EMC filter. Fulfil EN
55011 Class A2 and EN/IEC 61800-3
Category 3
H3:
H3 - Integrated EMC filter. Fulfil EN
55011 class A1/B and EN/IEC 61800-3
Category 1/2 (Enclosure type A1 only)
1)
H4: Integrated EMC filter. Fulfil EN
55011 class A1 and EN/IEC 61800-3
Category 2
H5: Marine versions. Fulfill same
emissions levels as H2 versions
Brake
18
B: Brake chopper included
X: No brake chopper included
T: Safe Stop No brake
1)
U: Safe stop brake chopper
1)
Display
19
G: Graphical Local Control Panel (LCP)
N: Numerical Local Control Panel (LCP)
X: No Local Control Panel
Coating PCB
20
C: Coated PCB
R: Ruggedised
X: No coated PCB
Mains option
21
X: No mains option
1: Mains disconnect
3: Mains disconnect and Fuse
2)
5: Mains disconnect, Fuse and Load
sharing
2, 3)
7: Fuse
2)
8: Mains disconnect and Load sharing
3)
A: Fuse and Load sharing
2, 3)
D: Load sharing
3)
Adaptation
22
X: Standard cable entries
O: European metric thread in cable
entries (A4, A5, B1, B2, C1, C2 only)
S: Imperial cable entries (A5, B1, B2, C1
and C2 only)
Adaptation
23
X: No adaptation
How to Order
VLT
®
AutomationDrive FC 301/FC 302 Design Guide, 0.25-75 kW
82
MG33BF02 - Rev. 2013-12-20
7
7
Содержание VLT AutomationDrive FC 301
Страница 2: ......
Страница 199: ...Index VLT AutomationDrive FC 301 FC 302 Design Guide 0 25 75 kW MG33BF02 Rev 2013 12 20 197...