10.321 (ID 656) Load Drooping Time
Location in the menu:
P2.6.9
(Multi-purpose Control Application)
Use this parameter to set the drooping time of the motor. Use load drooping to get a dynamic speed drooping when the load
changes. This parameter gives the time during which the speed is restored 63% of the change.
10.322 (ID 657) Current Control Time
Location in the menu:
P2.6.15.18
(Multi-purpose Control Application)
Use this parameter to adjust the integrator time constant of current controller. This value is presented in seconds.
10.323 (ID 662) Measured Voltage Drop
Location in the menu:
P2.6.18.16
(Multi-purpose Control Application, VACON
®
NXS)
P2.6.17.16
(Multi-purpose Control Application, VACON
®
NXP)
Use this parameter to set the measured voltage drop at stator resistance between two phases with the nominal current of the mo-
tor.
The measured voltage drop at stator resistance between two phases with the nominal current of the motor. This parameter is iden-
tified during the ID run. Set this value to gain the optimum torque calculation for Open Loop low frequencies.
10.324 (ID 664) IR: Add Zero Point Voltage
Location in the menu:
P2.6.18.17
(Multi-purpose Control Application, VACON
®
NXS)
P2.6.17.17
(Multi-purpose Control Application, VACON
®
NXP)
Use this parameter to set the amount of voltage that is fed to the motor at zero speed when the torque boost is used.
10.325 (ID 665) IR: Add Generator Scale
Location in the menu:
P2.6.18.18
(Multi-purpose Control Application, VACON
®
NXS)
P2.6.17.18
(Multi-purpose Control Application, VACON
®
NXP)
Use this parameter to set the scaling factor for the generating side IR-compensation when the torque boost is used.
10.326 (ID 667) IR: Add Motoring Scale
Location in the menu:
P2.6.18.19
(Multi-purpose Control Application, VACON
®
NXS)
P2.6.17.19
(Multi-purpose Control Application, VACON
®
NXP)
Use this parameter to set the scaling factor for the motoring side IR-compensation when the torque boost is used.
10.327 (ID 668) IU Offset
Location in the menu:
P2.6.18.20
(Multi-purpose Control Application, VACON
®
NXS)
P2.6.17.22
(Multi-purpose Control Application, VACON
®
NXP)
Use this parameter to set the offset value for the phase current measurement.
10.328 (ID 669) IV Offset
Location in the menu:
P2.6.18.21
(Multi-purpose Control Application, VACON
®
NXS)
P2.6.17.23
(Multi-purpose Control Application, VACON
®
NXP)
Use this parameter to set the offset value for the phase current measurement.
AB296635287482en-000301 / DPD00903 | 249
Danfoss A/S © 2023.02
Parameter Descriptions
VACON® NX All-in-One
Application Guide