1.
TP7000-RF
Press the recessed
RESET
button, using a non-
metallic object, to reset the unit.
2. Press & hold the recessed
LEARN
button for 3
seconds, using a non-metallic object.
NOTE: Thermostat now transmits continuously for 5 mins.
3.
RX1 -
Press and hold buttons
PROG and CH1
for 3 seconds until green light fl ashes once.
4.
RX2 (if applicable)
Stat 1 - perform steps 1-3.
Stat 2 - wait 5 mins, perform steps1-2 and then press
PROG and CH2
on RX2.
RX3 (if applicable)
Stat 1 - perform steps 1 – 3.
Stat 2 - wait 5 mins, perform steps 1-2 and then press
PROG and CH2
on RX3.
Stat 3 - wait 5 mins, perform steps 1-2 and then press
PROG and CH3
on RX3.
5.
TP7000-RF -
Press
or
to return the unit
to normal operation.
3.5 Commissioning (RF versions only)
If the thermostat and the receiver have been supplied together
in a combined pack, the units have been paired in the factory
and no commissioning is required (RX1 only).
To tune the RX receiver to the frequency of the thermostat signal, follow
steps 1-5 below.
RX1
LEARN
RESET
3.4 Receiver Wiring (RF models only)
1 2 3 4
ELECTRONICS
N L
COM
ZONE
1 ON
ZONE
1 OFF
A
ELECTRONICS
B C 1 2 3 4 5 6
N
L
ZONE
1 ON
ZONE
1 OFF
ZONE
2 ON
ZONE
3 ON
COM
TERMINAL 6
RX3 ONLY
RX1
RX2 & RX3
Note:
1) For mains voltage operated systems link terminal 2 to mains live supply.
2) Power supply to unit must not be switched by timeswitch.