Inspection
Inspect the orifice installed between the valve and adapter plate. This orifice must be installed in the
case drain passage for proper pressure limiter operation.
Reassembly
1. Install a new gasket (M11) on the housing. Place the adapter plate into position and install the screws
(M90). Torque the screws to 16 N•m [12 lbf•ft].
C
Caution
Protect exposed surfaces and cavities from damage and foreign material.
Install a sealing washer under the head of any mounting screws that are installed into through holes
in the housing.
2. Install new O-rings (W701A) and the orifice onto the solenoid valve assembly and install the solenoid
valve onto the adapter plate. Install screws (W702). Torque to 5.4 N•m [4 lbf•ft].
FNR removal/installation
P106 185E
M11
M90 (x6)
T80
T70
T50
T
T30
T40
W701A
M900
M1
d
I
5 mm
d
W702 (x4)
I
5 mm
Seal washer
location (42, 180, 250 cc)
16 N•m [12 lbf•ft]
5.4 N•m [4 lbf•ft]
Service Manual
Series T90 Axial Piston Pumps
Minor repair
©
Danfoss | March 2020
AX216086485386en-000101 | 63