C-40X Cabinet
The C-40X Stock Cabinet is designed specifically for the T-420-1
press and T-421U electric pump. Holes are pre-drilled so that the
press and pump can be mounted conveniently on top of the
cabinet. The C-40X cabinet has 40 heavy duty plastic drawers
which divide into two, three or four compartments providing
ample space for a large selection of hose ends and adapters.
CAUTION: It is recommended these instructions be read
thoroughly prior to set-up, and then used as a guide during
actual assembly.
STEP 1:
Remove packaging from C-40X cabinet.
STEP 2:
Remove shipping carton from T-420-1 press. There are
two 1/2”-13 tapped holes in top of plate which may be used for
lifting purposes (figure 1 ).
STEP 3:
Using an adequate lifting device, raise the press to the
left side of cabinet. Align holes in press support brackets with
predrilled holes in cabinet. Insert bolts (found in cabinet) through
top of cabinet. Washers and nuts are installed from underneath.
Tighten.
STEP 4:
The T-421U Electric Pump mounts on the right side of
the cabinet. Predrilled holes align the pump. Insert bolts through
top of cabinet. Washers and nuts are installed from underneath.
Tighten.
STEP 5:
Remove plug from outlet port in pump.
STEP 6:
Locate press/pump connecting hose assembly (T-410-
22) and remove 4315X8 For-Seal adapter. Thread adapter into
outlet port in pump (step 5).
STEP 7:
Connect Hose assembly (T-410-22) to For-Seal adapter
on press and pump. Tighten.
STEP 8:
Before the electric pump (T-421U) can be activated,
the male and female electrical disconnects must be mated. The
female half and wire harness is shipped with the T-421U pump.
Both male and female halves are keyed so that they can be con-
nected in only the correct position. After the connection is made,
tighten the knurled nut.
STEP 9:
Plug electric cord into a grounded 220 volt, 60 cycle,
single phase outlet. THE PUMP MUST BE ON A 15 AMP FUSED
ELECTRICAL CIRCUIT. If using T-421U-110 110v pump, plug elec-
tric cord into a grounded 110 volt, 60 cycle, single phase outlet.
The pump must be on a 30 amp fused electrical circuit.