Typical fully pumped system 

with 3-port mid-position valve

W

iring 

Replacement 

Please see overleaf for a table containing replacement 
wiring information. 

Some controls are connected in different ways depending 
upon the type of system and/or the controls which are 

fi

 tted. If there is any doubt about the way in which the 

existing unit is connected, please contact our Technical 
Services Department before proceeding with
replacement.

 

 

If the unit is to be used in association with a 6  

 

 

wire Honeywell Y Plan, a special wiring diagram  

 

 

may be required. Contact the Danfoss Randall  

 

 

Technical Services Department for details.

 

Note: The SET2E is a direct replacement for a Danfoss 
Randall SET2. 

 

!

N

L

1

2

3

4

5

6

3 amp fuse 

D.H.W.

HTG

ON

OFF

Mains 
Supply N

L

Programmer 

Terminals

L

N

N

N

Boiler & 

Pump

3-port 

mid-pos 

valve

Room 

Stat

 Cyl. 

Stat

ON

OFF

Содержание SET2E

Страница 1: ...SET2E Installation User Instructions electronic 24 hour mini programmer for heating hot water...

Страница 2: ...n 4 5 Wiring 5 7 Replacement 7 9 User What is a Programmer 10 Your programmer 11 Resetting the unit 11 Setting the clock 12 Factory pre sets 12 Programming the unit 12 13 Temporary overrides 13 14 Man...

Страница 3: ...ply 230 15 Vac 50 60Hz Switch action 2 x SPDT Type 1B Switch rating Max 264Vac 50 60Hz 3 1 A Timing accuracy 1 min month Power reserve minimum 10 hours Enclosure rating IP30 Max ambient temperature 45...

Страница 4: ...lplate 3 For mains voltage applications a link must be fitted between terminals L and 2 and between 1 and 5 4 Whilst the unit does not require an Earth connection a terminal is provided on the wallpla...

Страница 5: ...ition and the right hand rocker switch to the HW CH position The red LED should now be illuminated Adjust any remote thermostats to check the services operate correctly 9 Press the left hand rocker sw...

Страница 6: ...has been made to ensure the accuracy of this information it is recommended that the specific information relating to the ancillary controls is obtained from the manufacturers concerned N L 1 2 3 4 5...

Страница 7: ...h the existing unit is connected please contact our Technical Services Department before proceeding with replacement If the unit is to be used in association with a 6 wire Honeywell Y Plan a special w...

Страница 8: ...s 1 2 are linked and 5 6 are linked 4 DANFOSS RANDALL 3060 3020P 1 7 6 4 2 3 5 DANFOSS RANDALL 102 102E 5 3 6 1 2 DANFOSS RANDALL 701 N L 3 6 4 1 5 2 HONEYWELL ST6200 N L 3 1 4 2 HORSTMANN CORAL 423 4...

Страница 9: ...D CENTROLLER 60 1 2 5 4 3 SMITH IND CENTROLLER 10 N L 3 2 1 4 SMITH IND CENTROLLER 70 1 2 5 4 3 6 SMITH IND CENTROLLER 1000 N L 3 1 4 2 Programme selectors linked SWITCHMASTER 320 350 N 4 L 3 1 Termin...

Страница 10: ...anently off The time on the programmer must be correct Some types have to be adjusted in spring and autumn at the changes between Greenwich Mean Time and British Summer Time You may be able to tempora...

Страница 11: ...r constantly OFF During the summer the central heating can be turned off whilst still controlling the hot water at the set times Resetting the Unit IMPORTANT Before you start you should reset the unit...

Страница 12: ...unit is supplied with the following preset programme which will be active after the unit has been RESET see page 10 ON at 6 30am OFF at 8 30am ON at 5 00pm OFF at 10 30pm To alter these times to suit...

Страница 13: ...on and use W and X keys to set the time you want the programmer to next come on Move the slider to the 2nd OFF position and use W and X keys to set the time you want the programmer to next go off Temp...

Страница 14: ...of operation If the system is off it will come on If it is already on it will add an extra hour so the system stays on for an extra hour A bar on the right of the LCD will remind you that you have sel...

Страница 15: ...off and only the hot water is controlled according to the set programme Memory Backup IMPORTANT If the SET2E is ever disconnected from the mains the display will go blank but the unit will keep your...

Страница 16: ...Name Tel Visit our website www danfoss randall co uk Email our technical department drl_technical danfoss com Call our technical department 0845 121 7505 8 45 5 15 Mon Thurs 8 45 4 45 Fri For a large...

Отзывы: