Danfoss Secop 105N9502 Скачать руководство пользователя страница 4

4

FRCC.ES.011.A1.02

M

ANUAL

I

NTRODUCTION

1. The Bluetooth® gateway is battery driven. It is not fully charged upon new delivery.

    Charging the gateway may take up to 2 hours. The gateway may be used while charging.

2. When fully charged the gateway will run continuously 8 – 12 hours without power supply.

3. The maximum range is ~10 meters.

4. The Bluetooth® gateway may be permanently installed in an application.

     In permanent applications the charger enclosed upon delivery is used as a power supply.

5. If no serial communication occurs over a period of 60 seconds then the Bluetooth® gateway will

    shut down to conserve the battery. If the fi nding and pairing of the Bluetooth® device takes more

    than 60 seconds then the gateway will shut down. In the event that the gateway shuts down in the

    middle of an operation simply turn it on again and repeat the operation.

6. Requirements for Bluetooth® adapters:

    -  PC or adapter has to be a class 1 or class 2 Bluetooth® transmitter. The Secop Bluetooth® gateway is 

a class 2 transmitter.

    - Dedicated software has to support Bluetooth® serial ports.

Bluetooth® RS485 gateway with male DSUB-9 plug connector

    - USB power supply

    - DSUB-9 / RJ45 adaptor

Important to know

Contents of the package

The Secop Bluetooth® gateway is used in the connection between a controller and a computer when 

running Tool4Cool® software.

The gateway is equipped with a high-performance rechargeable battery, so an external power source is

not required. This makes the gateway particularly suitable in mobile applications.

Under normal circumstances no driver installation is required and the gateway functions fully 

independently of the operating system platform in use. However if problems arise, please refer to 

section 8.

Please read the instructions in this handbook before using the gateway for the fi rst time.

General Description

Содержание Secop 105N9502

Страница 1: ...www danfoss com Manual Danfoss commercial compressors SecopcompressorsproducedforDanfoss Bluetooth Gateway MAKING MODERN LIVING POSSIBLE...

Страница 2: ...2 FRCC ES 011 A1 02 MANUAL...

Страница 3: ...ching on 5 Charging the battery 5 Recommandations 5 Pairing the gateway 6 Windows XP 6 Windows 7 8 Configuring tool4cool 11 Technical data overview 13 Gateway status 14 Safety notes 15 Conformity with...

Страница 4: ...urn it on again and repeat the operation 6 Requirements for Bluetooth adapters PC or adapter has to be a class 1 or class 2 Bluetooth transmitter The Secop Bluetooth gateway is a class 2 transmitter D...

Страница 5: ...attery charger supplied with the gateway The time required for full charging is approximately 2 hours To charge the battery 1 Connect the charger to the USB port at the rear of the Bluetooth gateway 2...

Страница 6: ...er for your Windows XP computer 2 Turn on the Secop Bluetooth gateway by pressing briefly on the push button The LED will blink green Please note The gateway runs for 60 seconds before shutting down a...

Страница 7: ...to be found check box and then click Next 6 Click the Secop Bluetooth gateway shown in the dialog and then click Next 7 Click use the passkey found in the documentation and then type the passkey 1234...

Страница 8: ...er 2 Turn the Secop Bluetooth gateway on by pressing briefly on the push button The LED will blink green Please note The gateway runs for 60 seconds before shutting down automatically At each step of...

Страница 9: ...the passkey 1234 as shown then select Next 6 Select Close to complete the pairing Now look at the Control Panel Hardware and Sound Devices and Printers to confirm the Secop device is visible 7 Select...

Страница 10: ...GATEWAY 8 Under the Services tab make a note of the COM port to which the gateway is paired In this example it is COM13 Alternatively the COM port can be viewed in the Hardware tab of the Bluetooth de...

Страница 11: ...bar 3 Select Connect Network in the drop down menu 4 This dialog box will open In the Connect using field select the COM port to which the gateway is connected Note This is the COM port you noted dow...

Страница 12: ...s ensures that Tool4Cool will prevent the Bluetooth gateway from timing out and turning the power off Tool4Cool scans the network and detects changes Then click OK to return to the Connect Network dia...

Страница 13: ...r supply Battery Type Lithium Ion rechargeable battery 3 7V 540mAh Operating time Maximum 10 hours 115 2 kBit s fully charged Charging time Maximum 2 h DC interface DC power jack 0 65 mm 6 24 V DC sta...

Страница 14: ...ive Incoming connections are accepted LED alternates rapidly between red and green RS485 Bluetooth gateway is in normal operating mode RS485 COM HARDWA RE service is active A connection between PC and...

Страница 15: ...attery only for its intended purpose Do not expose the battery to water or extreme moisture Do not drop the battery or subject it to mechanical shocks Never use any charger or battery which is damaged...

Страница 16: ...ing which parameters and level of the controller the user is entitled to access For user access at a different level a new Product Key is required A separate Product Key is required for every individu...

Страница 17: ...s again as shown in 3 Pairing the gateway Many external Bluetooth adapters are delivered with BlueSoleil software drivers A test of the drivers shows that they may have problems with the communication...

Страница 18: ...18 FRCC ES 011 A1 02 MANUAL TROUBLESHOOTING 5 Select True in the RS485 menu 6 Click OK to confirm the change 7 Click OK again to enable network...

Страница 19: ...FRCC ES 011 A1 02 19 MANUAL...

Страница 20: ...ergy efficient solution that respects the environment and reduces total life cycle costs We have 40 years of experience within the development of hermetic compressors which has brought us amongst the...

Отзывы: