Fault Reaction Overview
Description
Monitoring
LED
Solenoid valves
Error pin output Reaction time
(ms)
Spool not at setpoint
Passive
—
High
250
Unable to reach float position
Passive
—
High
250
U
DC
> max.
Passive
Disabled
—
250
U
DC
< min.
Passive
———————
Disabled
—
250
U
S
out of range
Passive
—
High
250
LVDT error
Passive
—
High
250
Temp > max.
Passive
Disabled
High
250