The main features of PVEH:
•
Inductive transducer
•
Integrated pulse width modulation
•
Low hysteresis
•
Fast reaction time
•
Hirschmann or AMP connector
•
Fault monitoring with transistor output for signal source
•
Low electrical power
•
No set-up procedure
V310099.A
P
A
T
P
T
B
p
C
PVEH parameters
Supply voltage U
DC
Rated and Range
11 V to 32 V
Maximum ripple
5%
Current consumption at rated voltage
0.57 (0.33) A @ 12 V
0.3 (0.17) A @ 24 V
Signal voltage
Neutral
0.5 x U
DC
A-port
↔
B-port
0.25 • U
DC
to 0.75 • U
DC
Signal current at rated voltage
0.25 mA to 0.70 mA
Input impedance in relation to 0.5 • U
DC
12 KΩ
Input capacitor
100 ηF
Power consumption
7 (3.5) W
PVEH
Maximum load
100 mA
60 mA
Reaction
time at fault
Active / Passive
500 ms
250 ms
Technical Information
PVG 120 Proportional Valve Group
Electrical Actuation
520L0356 • Rev JA • Mar 2014
19
Содержание PVG 120
Страница 45: ...Technical Information PVG 120 Proportional Valve Group Order Specification 520L0356 Rev JA Mar 2014 45 ...
Страница 46: ...Technical Information PVG 120 Proportional Valve Group 46 520L0356 Rev JA Mar 2014 ...