9
520L0888
• Rev BB • Feb 2015
Service and Parts Manual
PVG 100 Proportional Valves
PVEH/PVEM/PVES
Adjustment of PVE
when max. lever travel is
exceeded
(PVE is factory-preset)
Check maximum lever travel in neutral position.
1. Make sure the system is supplied with hydraulic power.
2. Connect supply voltage (UDC) (Signal voltage 0.5 x UDC), or cut off the signal voltage (US) on
pin 2.
A
B
max. 2 [0.08]
ma
x. 2
[0
.08
]
Lever travel exceeded in
PVG 100
Direction of rotation for adjustment of position transducer
Direction A
Direction B
Turn of transducer
Movement of lever
1
/
4
1
/
2
3
/
4
1.5 mm [0.06 in]
3.0 mm [0.12 in]
4.5 mm [0.18 in]
Installation