
28 | © Danfoss | August 2018
AQ00000211
ENGINEERING TOMORROW
Parameter configuration
The PVED-CLS contains more than 170 configurable parameters, which are divided into 15 sectors and 3 different
PSAC user-levels (see tab “User” in the parameter list, paragraph 17.4), each having their own unlock code:
•
Danfoss (access to all parameters)
•
OEM
•
Dealer
Se
ct
o
r na
me
St
a
rt
a
ddr
es
s
E
nd a
ddr
e
ss
S
ect
o
r s
ize
(b
y
te
s)
A
cces
s t
y
p
e
CRC/
Ch
ec
k
su
m
ca
lc
ul
a
ti
o
n e
nd
a
ddr
es
s
CRC/
Ch
ec
k
su
m
a
ddr
es
s
CRC/
si
g
n
a
tu
re
a
ddr
es
s
P
SA
C
Hydraulic Config
3072
3121
50
R
ea
d
/W
rite
3097
3120
40
OEM
SEHS FDA
3122
3161
40
3134
3160
42
OEM
Valve Calibration Data
3162
3184
23
3171
3183
44
OEM,
Dealer
CAN WAS Calibration Data
3185
3204
20
3196
3203
46
OEM,
Dealer
Analog Sensor Calibration Data
3205
3236
32
3226
3235
48
OEM,
Dealer
Peripherals Config
3237
3286
50
3253
3285
50
OEM
SEHS Protocol Data
3287
3350
64
3330
3349
52
OEM
Internal Monitoring
3351
3420
70
3394
3419
54
OEM
Vehicle Geometry
3421
3450
30
3429
3449
56
OEM,
Dealer
GPS Config
3451
3520
70
3495
3519
58
OEM
STW Config
3521
3645
125
3585
3644
60
OEM
AUX Config
3646
3770
125
3742
3769
62
OEM
Production/Calibration Flag
3771
3790
20
3778
3789
-
OEM
Auto Calibration Config
3791
3863
73
3846
3862
64
OEM,
Dealer
OEM Data
4212
4311
100
-
-
-
-
Table 3
Attention
Unlock codes, for the different user levels, are managed by Danfoss technical support team and can only be aquired by
directly contacting the Danfoss technical support team!
Danfoss has developed a service tool (PLUS+1 SERVICE TOOL), and recommend the tool for:
•
Changing parameters in the EEPROM
•
Download of Software and bootloader
•
Enable/disable diagnostic messages (status messages 1 - 7) on the CANbus
•
Execute auto-calibration functionalities for WAS and Spool
•
Controlling the spool manually for diagnostic purposes
•
Extracting diagnostic data from the PVED-CLS (error history, temperature histograms etc.)
4.1
PARAMETER SETUP PROCEDURE – GOOD PRACTICE
When booting up a PVED-CLS for the very first time, it is good practice to follow this procedure:
Содержание PVED-CLS
Страница 6: ...6 Danfoss August 2018 AQ00000211 ENGINEERING TOMORROW ...
Страница 71: ... Danfoss August 2018 AQ00000211 71 ENGINEERING TOMORROW Figure 29 ...
Страница 127: ... Danfoss August 2018 AQ00000211 127 ENGINEERING TOMORROW ...
Страница 147: ... Danfoss August 2018 AQ00000211 147 ENGINEERING TOMORROW ...
Страница 182: ...182 Danfoss August 2018 AQ00000211 ENGINEERING TOMORROW ...