Danfoss PVE 4 Series Скачать руководство пользователя страница 2

520L0619

 • Rev EB • Mar 2014  

© Danfoss, 2014-03

DI general note

Til DI udførelserne er det nødvendigt at have 2 U

DC

-tilslutninger (U

DC

 og U

DC2

):

• U

DC

  forsyner elektronikken og

 •  U

DC2

 forsyner magnetventilerne

De to jordforbundne stikben er internt forbundet. 
Der kan med fordel anvendes to separate strømforsyninger (jvf. tekniske informationer for PVE serie 4)

On DI versions two U

DC

 connections (U

DC

 and U

DC2

) are necessary. 

• U

DC

 will supply the electronics and 

• U

DC2

 will supply the solenoid valves      

The two ground pins are internally connected.  
With advantages two separate power supplies can be used, see also Technical information for PVE series 4.

Die DI Ausführungen fordern zwei U

DC

-Anschlüsse (U

DC

 und U

DC2

):

• U

DC 

 versorgt die Elektronik und

• U

DC2

 versorgt die Magnetventile      

De zwei Erdungsstecker sind intern verbunden. 
Es kann mit Vorteil zwei separate Stromversorgungen verwendet werden (vgl. technische Informationen 
für PVE Serie 4)

Pour les versions DI deux raccordements U

DC

 (U

DC

 et U

DC2

) sont nécessaires.

• U

DC

 alimente l’électronique

• U

DC2

  alimente les électrodistributeurs      

Les deux bornes masse sont reliées intéreurement.
L’emploi de deux sources d’alimentation séparées a des avantages, voir Information Technique pour PVE 
série 4

Version ON/OFF

Connection PVEO with direction indication (DI)

Connector 1

A U

DC

B U

DC

Gnd

Gnd

AMP (grey)

p 1

p 2

p 3

p 4

Connector 2

DI-B

DI-A

Gnd

U

DC 2

AMP (black)

p  1

p 2

p 3

p 4

Connection PVEO standard

Connector

A

B

AMP/Hirschmann/DIN

pin 1

pin 2

Deutsch

pin 1

pin 4

Function

A (pin 1)

B (pin 2)

Neutral

0

0

Q:  P 

 A

U

DC

0

Q:  P 

 B

0

U

DC

Control all PVEO

Connector

A

B

AMP 

Hirschmann/DIN

pin 1

pin 2

Deutsch

pin 1

pin 4

 

y

Ground pins are internally 

connected.

 

y

Pin 3 is not connected on 

Hirschmann/DIN version of 

PVEO.

 

y

U

DC2

 supplies electronics for 

feedback signal on PVEO-DI.

AMP version of PVEO/PVEO–R

AMP version of PVEO–DI

Hirschmann/DIN version of PVEO / PVEO–R

Deutsch version of PVEO /PVEO-R

U

DC

U

DC

PVEO/PVEO-R

157-502.11

DC

DC

U

U

3

1

2

U

DC

U

DC

U

DC

U

DC

P301 104

Black connector

Grey connector

 DI-B

DI-A

PVEO-DI

1
2

4

3

Pin no.

 LED

U

DC

U

U

DC2

DC

U

DC

U

DC

All PVE variants. PVEO and PVEO-R are without LVDT

Содержание PVE 4 Series

Страница 1: ...n d kker Instruction covers Anleitung umfasst l instruction couvre Danfoss actuators PVEA PVEH PVEM PVEO PVEP PVES PVEU Variants R DI SP F Connectors Deutsch AMP DIN Hirschmann For full documentation...

Страница 2: ...UDC2 sont n cessaires UDC alimente l lectronique UDC2 alimente les lectrodistributeurs Les deux bornes masse sont reli es int reurement L emploi de deux sources d alimentation s par es a des avantage...

Страница 3: ...UDC 50 34 Q P B 0 5 0 65 UDC 50 65 Float 0 75 UDC 75 Standard PVE with DI Connection PVE with direction indication DI Connector 1 US UDC 1 Gnd Error AMP grey p 1 p 2 p 3 p 4 Deutsch p 1 p 4 p 3 p 2 Co...

Страница 4: ...separate float pin Control US for standard mounted PVEH PVEM float A six pin version Function Voltage relative PWM Neutral 0 5 UDC 50 Q P A 0 5 0 25 UDC 50 25 Q P B 0 5 0 75 UDC 50 75 Float UDC on Fl...

Страница 5: ...fault PVE Float six pin Active 500 ms Float not active High UDC Constant red Yes 750 ms Float still active 1 Measured between fault output pin and ground Direction Indication Feedback DI As shown in t...

Страница 6: ...EA PVEH PVES A port B port 0 25 UDC to 0 75 UDC PVEU neutral 5V PVEU A port B port 2 5V to 7 5V PVEP neutral A 10 B 10 PVEP A port 10 A 80 B 10 PVEP B port A 10 10 B 80 Signal currentat rated voltage...

Страница 7: ...eux dommages C est la raison pour laquelle il est important d analyser chaque aspect de l application Les vannes proportionnelles tant utilis es dans de nombreuses conditions d exploitation et applica...

Страница 8: ...ck yellow green blue 5 m 157B4974 AMP black coding 4 pin white blue yellow red 4 m 157B4995 Connector code numbers Part number Name 157B4992 AMP CONNECTING KIT GREY 4 pin with housing contact and wire...

Отзывы: