background image

When in a hospital or other health care facility, observe the restrictions on the use of cellular
communication equipment. Switch CS500 unit off, if instructed to do so by the guidelines posted in
sensitive areas.

The operation of cardiac pacemakers, other implanted medical device and hearing aids can be affected
by interference from CS500 unit's antennas placed close to the device.

If in doubt about potential danger, contact a physician or the manufacturer of the implanted medical
device to verify that it is properly shielded. Pacemaker patients are advised to keep CS500 unit and its
antennas away from the pacemaker while it is on.

Air traffic

Danger of interference caused by RF energy.

The operation of wireless appliances in an aircraft is forbidden to prevent interference with
communications systems. Failure to observe these instructions may lead to the suspension or denial of
cellular services to the offender, legal action, or both.

Switch the unit off before boarding an aircraft.

Make sure it cannot be switched on inadvertently.

Explosives

Danger of explosion.

Operation of any electrical equipment in potentially explosive atmospheres can constitute a safety
hazard.

Observe the applicable regulations and precautions when you are near explosive areas (i.e. petrol
stations, fuel depots, chemical plants or where blasting operations are in progress).

Do not mount the antenna in the close environment of fuel tanks, vessels with explosives and
insufficiently shielded electronic devices.

Antennas

Danger due to absorption of RF energy.

Mobile communication devices may pose a health risk when operated in close proximity of persons.

Install the device with integrated antenna(s) used for the CS500 to provide a separation distance of at
least 20 cm / 8 inches from all persons.

Do not operate them in conjunction or co-locate them with any other antenna or transmitter.

Electronic equipment

Danger of interference caused by RF energy

The unit receives and transmits radio frequency energy while switched on. Interference may occur if it is
used close to TV sets, radios, computers or inadequately shielded equipment.

Follow any special regulations and always switch off the unit wherever use is forbidden, or when you
suspect that it may cause interference or danger.

Avoid property damage

W

Warning

Property damage may occur, and unintended movement of machine or mechanism may cause injury to
the technician or bystanders. Before any installation of the Control system, turn ignition lock off and
disconnect the battery. Before handling the device disconnect externally. Also, disconnect independently
supplied output load circuits.

Technical Information

PLUS+1® Connect CS500 IoT Gateway

Safety information

 

©

 Danfoss | October 2021

BC397226723595en-000101en-000101 | 11

Содержание PLUS+1 Connect CS500

Страница 1: ...Technical Information PLUS 1 Connect CS500 IoT Gateway www danfoss com...

Страница 2: ...Revision history Table of revisions Date Changed Rev October 2021 First edition 0101 Technical Information PLUS 1 Connect CS500 IoT Gateway 2 Danfoss October 2021 BC397226723595en 000101en 000101...

Страница 3: ...100 12 Ordering information Related products 13 Device functions Operations 14 GNSS Global Navigation Satellite System 14 Wireless Solution 14 SIM card 14 Input output functions I O 14 CAN interfaces...

Страница 4: ...CS500 Dimensions 22 Mounting Technical Information PLUS 1 Connect CS500 IoT Gateway Contents 4 Danfoss October 2021 BC397226723595en 000101en 000101...

Страница 5: ...s with components of other manufacturers CS500 literature references Reference literature Literature title Literature type Literature number PLUS 1 Connect CS500 Technical Information PLUS 1 Connect C...

Страница 6: ...low 1 Mounting Holes 2 GPS connector 3 Cellular 4G connector 4 LEDs 5 Power CAN MFIO connector 6 Label Type label The CS500 type label is located on the side of the enclosure CS500 type label informat...

Страница 7: ...rrectly mounted or maintained equipment Danfoss does not assume any responsibility for PLUS 1 products being incorrectly applied or the system being programmed in a manner that jeopardizes safety All...

Страница 8: ...will be voided if device is opened Device is not field serviceable Do not open the device Technical Information PLUS 1 Connect CS500 IoT Gateway Device Elements 8 Danfoss October 2021 BC397226723595e...

Страница 9: ...0R 06 11848 PTCRB This device has been certified for use on PTCRB Mobile Network Operator networks For more information see the certified device section http ptcrb com PLUS 1 Compliance Danfoss CS100...

Страница 10: ...anufacturer This device is designed to be used in systems which must be checked for conformity with legal requirements prior to placing into operation The integrator of this device is responsible to c...

Страница 11: ...tions fuel depots chemical plants or where blasting operations are in progress Do not mount the antenna in the close environment of fuel tanks vessels with explosives and insufficiently shielded elect...

Страница 12: ...e installation of the control system The following is recommended when welding on a machine equipped with electronic components Turn the engine off Remove electronic components from the machine before...

Страница 13: ...500 IoT Gateway and Antenna Kit 11247193 Replacement CS500 IoT Gateway 11247192 Replacement Antenna 11247194 DEUTSCH mating connector bag assembly 10102025 16 to 20 AWG 10100944 20 to 24 AWG Technical...

Страница 14: ...and Galileo satellites It can process data from multiple navigation systems simultaneously this increases the accuracy The CS500 uses GNSS as a time source When GNSS sync is not available the local ti...

Страница 15: ...nnect portal PLUS 1 Service Tool or programmatically with PLUS 1 GUIDE to monitor the machine state performance and position Both position and machine data are periodically transmitted and stored to t...

Страница 16: ...e where it is level with the local geographic horizon and has full view of the sky above Power Supply CAN Bus I O Connector 1 Pin Designation Description 1 Ground Power supply 2 9 to 36 VDC Power supp...

Страница 17: ...Certification Interface Protocol Certification CAN bus network 2 ISO 11898 2 High Speed 2 0A B Multifunction Input 2 DIN AIN ResIN FreqIN CrntIN CL15 DOUT Radio Module Cat 1 TE with 3G Fallback Cat 1...

Страница 18: ...7 V Frequency input middle range Description Unit Minimum Typical Maximum Comment Range Hz 0 10000 In steps of 1 Hz Range phase and quad Hz 0 5000 In steps of 1 Hz Rising voltage threshold V 3 89 Volt...

Страница 19: ...32 1 32 1 33 Input impedance to 5V Outputs Digital output Description Unit Minimum Maximum Comment Output Voltage range V 0 36 Current mA 0 3000 Do not connect a digital output to battery back drive...

Страница 20: ...D light correct sequence The LED lights up green constantly during the first second The LED starts to flash Problem with connection to PLUS 1 Connect portal After connecting to power supply the LED sh...

Страница 21: ...operate the device unless temperature is between 40 C and 75 C 40 F and 167 F Do not store and or transport the device unless it is kept at a temperature between 40 C and 85 C 40 F and 185 F Disposal...

Страница 22: ...CS500 Dimensions Technical Information PLUS 1 Connect CS500 IoT Gateway CS500 Technical Drawings 22 Danfoss October 2021 BC397226723595en 000101en 000101...

Страница 23: ...ector wires Antenna must be mounted on external surface with a view to the sky C Caution Device damage may occur Use caution when installing CS500 Due to the size of the mating connector wire bundle i...

Страница 24: ...Power Solutions US Company 2800 East 13th Street Ames IA 50010 USA Phone 1 515 239 6000 Danfoss Power Solutions Trading Shanghai Co Ltd Building 22 No 1000 Jin Hai Rd Jin Qiao Pudong New District Sha...

Отзывы: