4
Technical Specifications
Type
Specifications
Pressure sensor
Piezo resistive true differential
Pressure range
10 bar
Max. overpressure
Positive side: 15 bar
Negative side: 10 bar
Non-linearity and hysteresis error
0.15% of pressure range
Temperature error
1.5% over ambient and medium temperature
Medium temperature
-5 to 90°C
Ambient temperature
-5 to 50°C
Storage temperature
-5 to 50°C
Pressure connection
R21 quick couplers
Batteries
2 x AA NiMH rechargeable
Power consumption
Max. 55 mA
Display
128 x 64 monochromatic, backlight
Keyboard
3 keys
Pressure units
11
Flow units
11, incl. US units
k
V
-range
0 to 99999, with 0.1 step
Dimensions
94 x 218 x 35 mm
Weight
600 g, incl. batteries
Cover
IP65
Calibration validity
12 months
5
Ordering PFM 100
No.
Type
Set / pcs
Danfoss code no.
1
FPM 100 Measuring Instrument
1
003L8260
6
Spare Part List
No.
Type
Set / pcs
Danfoss code no.
1
Measuring hose, 2 x 1.5 m
1 set
003L8261
2
Needle
1 pcs
003L8262
3
Quick coupling
1 pcs
003L8263
4
Filters
1 set
003L8264
5
Strap
1 pcs
003L8265
User Guide
PFM 100 Measuring Instrument
Danfoss A/S
Heating Solutions
Haarupvaenget 11
8600 Silkeborg
Denmark
Phone:+45 7488 8000
Fax: +45 7488 8100
Email: [email protected]
www.heating.danfoss.com
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective
companies. Danfoss Heating Solutions and the Danfoss Heating Solutions logotype are trademarks of Danfoss A/S. All rights reserved.
VUE2D
2
02
Produced by Danfoss Heating Solutions ©
0
8
/201
6
6
ASV-I/M measuring KIT for PFM100
1 s
et
003L82
74