![background image](http://html1.mh-extra.com/html/danfoss/paht-g-10/paht-g-10_disassembling-and-assembling_3815584010.webp)
Instruction
Disassembling and assembling PAH 10-12.5, PAHT 10-12.5 and PAHT G 10-12.5
10
180R9095 / 521B0986 / DKCFN.PI.010.NA3.02 / 09.2013
3. Assembling
2.
Parts and tools required for assembly.
Check that all parts are OK.
Replace all seals.
3.
Mount the O-ring on the flange.
4.
Mount the port plate in its right position
using the pin as guide.
Guide
pin
WARNING:
Do not use silicone when assembling the
pump. Do not reuse disassembled O-rings;
they might be damaged. Always use new
O-rings.
1. Lubrication:
•
To prevent seizing-up, lubricate all threads
with PTFE lubrication type.
•
O-rings inside pump may be lubricated
only with clean filtered water.
•
O-rings for port flange, mounting flange
and flushing valve must be lubricated.
•
It is important to lubricate ALL parts to be
assembled with clean filtered water
(Especially all PEEK parts).
Important:
It is essential that the pump is serviced in
conditions of absolute cleanliness. All parts
must be absolute clean before mounting.