manualshive.com logo in svg
background image

4 | AN36292867744601-000101

© Danfoss | DCS (vt) | 2021.02

Configuration

Condensed programming menu

Enables the rapid configuration of the most frequently-used parameters (

SP, C1, d0, d1, d4, F3, A1

 and 

A2

). Press the 

SET

 key for 3 

seconds to access it.

Extended programming menu

Use the extended programming menu to configure all of the unit’s parameters in order to adapt it to installation requirements. Press the 

SET

 key for 6 seconds to access it.

Regulation and control

Important:

•  If the function of the password has been configured as a keypad block (

b10

=2), or as an access block to parameters (

b10

=1), you 

will be requested to enter the access code programmed in 

PAS

 when attempting to access either of the two functions. If the entered 

password is not correct, the unit will go back to showing the temperature.

•  Certain parameters or menus may not be visible depending on the configuration of the rest of the parameters.

Level 1

Level 2

Description

Values

Min.

Def.

Max.

rE

SP

Temperature setting (Set Point)

ºF

-58

32.0

210

C0

Probe 1 calibration (Offset)

ºF

-36.0

0.0

36.0

C1

Probe 1 differential (Hysteresis)

ºF

0.1

3.6

36

C2

Set Point top locking (it cannot be set above this value)

ºF

-58

210

210

C3

Set Point bottom locking (it cannot be set below this value)

ºF

-58

-58

C2

C4

Type of delay for the protection of the compressor:

0

=Minimum time of compressor in OFF

1

=Minimum time of compressor in OFF and in ON in each cycle

0

0

1

C5

Protection delay time (Value of the option selected in parameter C4)

Min.

0

0

120

C6

COOL relay status with fault in probe 1:

0

=OFF; 

1

=ON; 

2

=Average according to last 24 h prior to probe error

3

=ON-OFF according to prog. C7 and C8

0

2

3

C7

Relay time in ON in the event of probe 1 failure
(If C7=0 and C8≠0, the relay will always be disconnected in OFF)

Min.

0

10

120

C8

Relay time in OFF in the event of probe 1 failure
(If C8=0 and C7≠0, the relay will always be connected in ON)

Min.

0

5

120

C9

Maximum duration of the continuous cycle mode. (

0

=deactivated)

H.

0

0

48

C10

Variation of the Set Point (SP) in continuous cycle mode. When it reaches this point 
(SP+C10), it reverts to the normal mode. (SP+C10 ≥ C3).
The value of this parameter is always negative, unless it is 0. (

0

=OFF)

ºF

0

-90

C3-SP

C12

Variation of the Set Point (SP) when the change Set Point function is active. (SP+C12 ≤ 
C2) (

0

= deactivated)

ºF

C3-SP

0.0

C2-SP

C19

Maximum start time from Pump Down
(Values between 1 and 9 seconds will not be accepted) (

0

=deactivated)

Sec.

0

0

120

C20

Maximum time for pump down (

0

= deactivated)

Min.

0

0

15

C21

Probe to be displayed 

0

=All probes (sequential)

1

=Probe 1 (Cold Room), 

2

=Probe 2 (Evaporator), 

3

=Probe 3 (According to I20)

0

1

3

C22

Stop fans and compressor on opening door 

0

=No, 

1

=Yes

0

0

1

C23

Start-up delay for fans and compressor with door open

Min.

0

0

999

C27

Probe 3 calibration (Offset)

ºF

-36.0

0.0

36.0

EP

Exit to level 1

Содержание Optyma AK-RC 251

Страница 1: ...are programmable and their operation depends on the configuration The function of the digital inputs depends on the configuration The recommended currents and powers are the maximum working currents a...

Страница 2: ...pressing once mutes the acoustic alarm Pressing for 3 seconds accesses the Set Point setting Indicators Fixed Stand By Mode activated Regulation is paused Flashing Controlled shutdown process for the...

Страница 3: ...ters Diagram to be used Cold regulation Defrost Evaporator fans o00 I00 I10 I11 I20 I21 d1 d7 F3 0 Demo Mode it displays the temp but does not regulate or activate relays 1 Solenoid Electric Yes 0 2 0...

Страница 4: ...0 Minimum time of compressor in OFF 1 Minimum time of compressor in OFF and in ON in each cycle 0 0 1 C5 Protection delay time Value of the option selected in parameter C4 Min 0 0 120 C6 COOL relay s...

Страница 5: ...en the compressor shuts down 0 No 1 Yes 0 0 1 F3 Status of the fans during the defrost 0 Shut down 1 Running 0 0 1 F4 Delay of start up after defrost If F3 0 It will only actuate if it is higher than...

Страница 6: ...ure switch 8 Remote Stand by 0 8 I11 Polarity of the digital input 1 0 Activates on closing contact 1 Activates on opening contact 0 1 I20 Configuration of digital input 2 0 Deactivated 1 Door contact...

Страница 7: ...in A1 has been reached AL Minimum temperature alarm in control probe The temperature value programmed in A2 has been reached AE External alarm activated by digital input AES Severe external alarm act...

Страница 8: ...15 A 250 V UL 60730 9 FLA 54 LRA 240 V AC UL 60730 RES 12 A 240 V AC NC EN60730 1 15 13 A 250 V UL 60730 6 FLA 36 LRA 240 V AC UL 60730 RES 6A 240 V AC Relay AUX 2 SPDT 16 A NO EN60730 1 12 9 A 250 V...

Страница 9: ...i n debe tener en cuenta las normas locales vigentes Los rel s AUXILIARES son programables y su funcionamiento depende de la configuraci n La funci n de las entradas digitales depende de la configurac...

Страница 10: ...ica Presionar este bot n durante 3 segundos accede al ajuste del Set Point de temperatura Indicadores Fijo Modo Stand By activo el control del cuarto fr o esta detenido Intermitente Proceso de paro co...

Страница 11: ...laci n Par metros Diagramma a utilizar Regulaci n del fr o Deshielo Ventiladores evaporador o00 I00 I10 I11 I20 I21 d1 d7 F3 0 Modo demo muestra temperatura en pantalla pero no regula temperatura ni a...

Страница 12: ...el compresor 0 Tiempo m nimo del compresor en OFF 1 Tiempo m nimo del compresor en OFF y en ON en cada ciclo 0 0 1 C5 Tiempo de retraso de la protecci n Valor de la opci n elegida en par metro C4 Min...

Страница 13: ...rar compresor 0 No 1 Si 0 0 1 F3 Estado de los ventiladores durante el deshielo 0 Parados 1 Encendidos 0 0 1 F4 Retraso de arranque despu s del deshielo Si F3 0 Solo se activa si es superior a d9 Min...

Страница 14: ...baja presi n 8 Stand by remoto 0 8 I11 Polaridad de la entrada digital 1 0 Activa en contacto cerrado 1 Activa en contacto abierto 0 1 I20 Configuraci n de la entrada digital 2 0 Desactivada 1 Contact...

Страница 15: ...ado el valor de temperatura programado en A1 AL Alarma de temperatura m nima en sensor de control Se ha alcanzado el valor de temperatura programado en A2 AE Alarma externa activada por entrada digita...

Страница 16: ...0 V AC UL 60730 RES 12 A 240 V AC NC EN60730 1 15 13 A 250 V UL 60730 6 FLA 36 LRA 240 V AC UL 60730 RES 6A 240 V AC Relevador AUX 2 SPDT 16 A NO EN60730 1 12 9 A 250 V UL 60730 5 FLA 30 LRA 240 V AC...

Отзывы: