3. General warranty issues

Component warranty is provided through the system manufacturer. All 

questions concerning warranty must be made with the system Original 

Equipment Manufacturer.  Danfoss will not honour any warranty claims 

made directly to Danfoss from the end-user.

Danfoss will furthermore not accept warranty claims on components 

having operated outside the general and specific performance specifi-

cations and guidelines.

Spare parts and components are available through the system provider.

5. Safety

The Nessie Plug&Spray

TM

 unit is capable of generating very high pres-

sure that can be harmful to human beings. It is recommended to wear 

appropriate personal protection equipment when commissioning and 

servicing the system.

6. System design

The Plug&Spray

TM

 units are designed for humidification and adiabatic 

cooling with high-pressure atomization. The units come in a constant 

speed version with IEC or Nema electric motor as well as in a version 

with constant pressure regulation using a Danfoss FCM 300 variable 

speed drive motor.  

The Plug&Spray

TM

 units are available with 6 different pump sizes (see 

technical data) to match the required flow demand. The motor power 

is dimensioned to provide design flow at a system pressure of max. 100 

bar or 1450 psi. 

The Nessie high-pressure axial-piston pumps provide excellent pres-

sure stability at high efficiency and low noise level. Accumulators are 

superfluous. The Plug&Spray

TM

 units comprise all necessary compo-

nents to ensure the best possible performance, maximum service life 

with maximum protection of the pump. The units are very compact 

and require very little space and are suitable for both wall and floor 

mounting.  

4. Identification

The Plug&Spray

TM

 unit carries a nameplate sticker on the mounting 

plate indicating type and serial number of the unit. The pump carries a 

nameplate sticker too.

Please have all serial numbers and code numbers handy for service 

claims.   

MADE IN DENMAK

Содержание Nessie Plug&Spray NPS 1CS

Страница 1: ...e Ionized Reverse Osmosis Danfoss defines clean tap water as water filtered to 10 m absolute value than 5000 This means that the water is filtered to a level where 99 995 of all particles larger than1...

Страница 2: ...The units come in a constant speed version with IEC or Nema electric motor as well as in a version with constant pressure regulation using a Danfoss FCM 300 variable speed drive motor The Plug SprayT...

Страница 3: ...The upper support part is inserted into the bottom part during instal lation and joined together with the supplied screws NB The mounting plate must be fixed to the floor with 4 bolts to secure the sy...

Страница 4: ...directions must be followed under any circumstance 8 1 Basic unit without electrical connecting box Constant speed version CS Electric motor The electric motor is a standard IEC or Nema AC motor and...

Страница 5: ...ired and prepared for direct power supply connection The following connections must be made 3 phase power supply 3 400 V Start signal through external potential free contact Fault relay Please refer t...

Страница 6: ...alve preventing return flow into the supply The water temperature must be kept between 3 and 50 C respec tively 37 and 122 F The supply pressure must not exceed 2 and 4 bar In case of unstable or peak...

Страница 7: ...nd check again With units with drive motor FCM 300 please check the programming see section on programming of the FCM 300 below Flushing the system The Plug SprayTM units are protected from factory ag...

Страница 8: ...als 1000 rpm 33 Hz for NPS 10 12 5 VS equals 1000 rpm 202 max output frequency 50 Hz equals 3000 rpm 85 Hz for NPS 10 12 5 equals 2400 rpm 215 Preset reference 1 Depends on application see description...

Страница 9: ...ter housing and the used cartridge Attach the gaskets on both ends thin type to the new cartridge Insert the new cartridge Please be careful with the O ring in the filter housing Turn the filter house...

Страница 10: ...l h 75 l h 100 l h Maxi mum flow at 100 bar 75 l h 100 l h 200 l h 300 l h 500 l h 750 l h 1000 l h 300 l h 450 l h 600 l h 1000 l h 1350 l h 1750 l h Motor type 0 55 kW 6 pole 0 75 kW 4 pole 1 5 kW 4...

Страница 11: ...0 55 kW NPS 1 CS IEC 180N0671 Electric motor 0 75 kW NPS 2 CS IEC 180N0371 Electric motor 1 5 kW NPS 3 2 4 CS IEC 180N0021 Electric motor 2 2 kW NPS 6 3 CS IEC 180N0280 Electric motor 3 kW NPS 10 CS...