MP20V analog outputs
The analogue outputs, that are different for MP20A or MP20V, have a common contact at pin 47 of the
connector. This pin is connected to pin 46 (stop) for powering up the 1-8 outputs.
Nsa1-Nsa8 have a common contact at pin 47 of the connector. Pin 47 connects with pin 46 (STOP) in
order to feed nSA1-nSA8 outputs. Maximum 20mA per output.
The MP20V allows to choose the control voltage in order to set the output power with the selection of 2
switches. Control voltage options: 0-5V, 0-10V, 0-Vcc.
User Manual
MP20V Receiver
Installation
©
Danfoss | January 2019
BC292570533618en-000101 | 11
Содержание MP20 Series
Страница 1: ...User Manual Remote Control MP20V Receiver www danfoss com...
Страница 10: ...User Manual MP20V Receiver Installation 10 Danfoss January 2019 BC292570533618en 000101...
Страница 14: ...User Manual MP20V Receiver 14 Danfoss January 2019 BC292570533618en 000101...
Страница 15: ...User Manual MP20V Receiver Danfoss January 2019 BC292570533618en 000101 15...