4 Electrical Installation
Refer to the safety warnings in
before
installing the MCO.
Screen all control cables and connect the cable screen to
ground at both ends to avoid EMC problems. Always
follow the instructions of the encoder supplier. See also
VLT
®
AutomationDrive FC 301/FC 302 0.25-75 kW Design
Guide
for more information regarding cable installation.
4.1 MCO 350/351 Control Terminals
4.1.1 Enclosure Types A2 and A3
Encoder and I/O terminal are located behind the C option
terminal cover, see
MCO CAN bus terminals and debug terminals (RS-485) are
on the top of the C option cover. If these connections are
used, cut out the plastic parts above the connectors and
mount the cable relief.
130BA248.11
Illustration 4.1 Location of Encoder and I/O Terminals
4.1.2 Enclosure Types A5, B1, and B2
All MCO 350/351 terminals are located next to the VLT
®
AutomationDrive control card. Remove the front cover to
get access. See
.
MCO control terminals are plug connectors with screw
terminals. Terminals X55, X56, X57, X58, and X59 are
duplicated to be used for both bookstyle and compact
enclosure type.
See
to locate the terminal blocks.
130B
T334.10
Illustration 4.2 Removing the Front Cover
Electrical Installation
Operating Instructions
10
Danfoss A/S © 04/2014 All rights reserved.
MG33R302
4
4