Adapter for RTD valves (accessory)

1.

2.

Place the RTD adapter on the valve as shown.

Hand-tighten the RTD adapter (max. 5 Nm).

Adapters for M28 valves (accessories)

Please follow the instructions supplied with the valve adapter for the specific M28 valve.

1.5  Inserting the batteries

Remove the battery cover and insert two AA batteries. Make sure the 

batteries are correctly oriented.

Rechargeable batteries 

must not

 be used.

When replacing batteries the programme settings will be preserved, 

but after two minutes the settings for time and date are reset.

The low battery symbol 

 is displayed approx. one month before the 

batteries run out.

After approx. two weeks the 

 symbol will flash 14 times from 19:00 

to 21:00 hrs.

Before the batteries run out 

living connect

®

 will leave the valve in a 

slightly open position to protect the valve from damage.

1.6  Using the buttons

living connect

®

 has two arrow buttons 

 which allow you to navigate 

the display and the menus and to set the temperature*.

The dot button   is used to select and confirm.

If the display is off, press either button to activate the display.

*The temperature is usually controlled via Danfoss Link™ CC, but may be 

changed at any time using the thermostat’s buttons. If this is done, the 

thermostat sends a message to Danfoss Link™ CC, instructing it to synchro-

nise the other thermostats in the same room.

Installation Guide 

living connect®

Содержание living connect

Страница 1: ...Danfoss Heating Solutions VIIDH102 11 2013 1 Installation and User Guide living connect Electronic Radiator Thermostat...

Страница 2: ...8 1 8 Automatic adjustments 8 1 9 Removing living connect 9 1 10 Resetting living connect to default settings 9 1 11 Removing an adapter from living connect 10 2 Technical specifications 11 Pay a vis...

Страница 3: ...g living connect to a Danfoss Link system 4 1 Configuring rooms in Danfoss Link CC 12 4 2 Connecting living connect to Danfoss Link CC 12 4 3 Testing the connection 14 5 Additional settings 5 1 Adjust...

Страница 4: ...e mounted adapter for Danfoss RA valves two alkaline AA batteries a 2 mm Allen key and a Quick Guide in languages English German Danish Dutch French Polish Swedish and Finnish living eco Quick Start G...

Страница 5: ...are available as accessories Adapter type Code no Adapter Valve For Danfoss RA valves 014G0251 For M30 x 1 5 K valves 014G0252 For Danfoss RAV valves 014G0250 34 For Danfoss RAVL valves 26 For Danfoss...

Страница 6: ...the 2 mm Allen key Adapter for M30 x 1 5 K valves 1 2 Place the K adapter on the valve as shown Hand tighten the K adapter max 5 Nm Adapter for RAV valves accessory 1 2 Click the inner adapter on the...

Страница 7: ...ol is displayed approx one month before the batteries run out After approx two weeks the symbol will flash 14 times from 19 00 to 21 00 hrs Before the batteries run out living connect will leave the v...

Страница 8: ...f operation living connect will shut off the radiator heat and then open again to detect the exact opening point of the valve This will allow living connect to control the heat as efficiently as possi...

Страница 9: ...dicate that Installation Mode is activated 3 4 Remove the battery cover and the batteries Insert the Allen key or similar into the hole to lock the adapter ring Turn counterclockwise to unscrew living...

Страница 10: ...t a small hex key or similar into the locking hole to lock the adapter ring 3 4 With the hex key locking the adapter ring turn the adapter in the shown direction Put back the battery cover Mount livin...

Страница 11: ...ttery level is critical the whole display will flash Ambient temperature range 0 to 40 C Transportation temperature range 20 to 65 C Maximum water temperature 90 C Temperature setting range 4 to 28 C...

Страница 12: ...Danfoss Link system 4 1 Configuring rooms in Danfoss Link CC Make sure that the room in which living connect has been installed has been configured in Danfoss Link CC see installation guide for Danfo...

Страница 13: ...r No 6 Heating System Mode Decide what the heating system prioritizes Heating with low return temperature recommended for district heating Fast heating with warm radiators recommended for boilers Mode...

Страница 14: ...m and antenna symbols will both be flashing Refer to Technical questions at www living danfoss eu 5 Additional settings 5 1 Adjusting to radiator room conditions Press for at least 3 seconds until M i...

Страница 15: ...s preventing it from detecting the decreasing temperature 5 3 Automatic valve exercising To keep the radiator valve functional and at its best living connect automatically exercises the valve every Th...

Страница 16: ...n and User Guide living connect Danfoss A S Haarupvaenget 11 DK 8600 Silkeborg Denmark Phone 45 7488 8000 Fax 45 7488 8100 www danfoss com www living danfoss eu Installer VIIDH102 Produced by Danfoss...

Отзывы: