Charger and battery
Disposal note:
This symbol on the product indicates that it may not be disposed of as household waste.
It must be handed over to the applicable take-back scheme for the recycling of electrical equipment.
•
Dispose of the product through channels provided for this purpose.
•
Comply with all local and currently applicable laws and regulations.
BC70K and BT11K specifications
BC70K battery charger
Specification
Value
AC power supply
110 – 230 V, 50/60 Hz, ± 10%, automatic switching
DC power supply, nominal
12 – 24 V
BT11K battery
Specification
Value
Voltage
3.7 V
Capacity
1130 mAh Li-Ion
Charging temperature
0°C to 45°C
Discharge temperature
-20°C to 60°C
Charging mode
Fast (<2.5 h) and intelligent
Weight
23 g
BC70K Battery Charger Set-up
The battery charger has two charging compartments that can simultaneously charge two BT11K
batteries. Use the information below to set up the BC70K battery charger.
1. Connect the charger to a power source using the cable provided.
The red LED will switch on if the charger is properly connected.
2. Place the batteries in the charger.
3. Optional: If charging two batteries, wait at least five seconds before inserting the second battery into
the compartment.
W
Warning
Possible damage to battery.
Be sure to charge batteries in environments with temperatures over 0°C.
User Manual
Remote Control IK2 Transmitters
Charger and battery
12 |
©
Danfoss | May 2021
BC290862531428en-000201