© Danfoss | FEC | 2020.03
AN29434614196101-000401 | 088N2112 00 | 9
Installation Guide
Danfoss Icon™ Master Controller 24V
EN
Technical data
Common characteristics, all Danfoss Icon™-products
Temperature for the ball pressure test
75 °C
Control polution degree
Degree 2, normal household environment
Software class
Class A
Rated impulse voltage
4 kV
Operating time
Permanently connected
Temperature range, storage and transportation
-20 °C to +65 °C
Dispossal instructions
The product must be disposed as electronic waste.
Full data sheet available at www.danfoss.com
Radio Module & Repeater
Purpose of control
Transmitting and receiving device
Ambient temperature range, continious use
0 °C to 40 °C
Frequency
868,4–869,85 MHz
Transmission power
<2,5 mW
Encapsulation (IP Class)
IP 20
Conformity declared acc. to following directives
RED, RoHS, WEEE
Protection class
Radio: Class III Construction, Repeater: Class II Construction
Supply voltage
Radio: 5 V DC, Repeater: 230 V AC 50/60 Hz
App Module
Purpose of control
Wi-Fi transmitting and receiving device, incl. Bluetooth
Ambient temperature range, continious use
0 °C to 40 °C
Frequency
2,4 GHz
Encapsulation (IP Class)
IP 20
Conformity declared acc. to following directives
RED, RoHS, WEEE
Protection class
Radio: Class III
Supply voltage
5 V DC
Master Controller 24V and Expansion Module (optional)
Supply voltage
220-240 V AC
Supply frequency
50/60 Hz
Output voltage, actuators
24 V DC
Max. power consumption per actuator output
2 W
Number of actuator outputs (1 actuator per output terminal) 10 or 15 depending on type
Output voltage, thermostats
24 V DC
Stand-by consumption per thermostat
0,2 W
Max. number of thermostats
10 or 15 depending on type
Max. length of wire from master controller to a 24 V ther-
mostat (depends on cable type used)
If 2 × 2 × 0,6 mm² STP/UTP: 100 m
If 2 × 0,5 mm²: 150 m
If > 2 × 0,75 mm²: 200 m
Stand-by consumption, Master Controller
< 2 W
Max. power consumption, excluding use of PWR 1 and PWR
2 outputs
< 50 W
Internal protection (fuse, non-replacable)
2,5 A
Output “Relay”
Micro-disconnection (Type 1.B action), Max. 2 A load
Actuator outputs, type
Electronic disconnection (Type 1.Y action)
Output “PWR 1”, type and rated max. output
Micro-interruption (Type 1.C action)
Output “PWR 2”, type and rated max. output
Type: Permanent output, Always live 230 V, Max. 50 W
Output “PWR 3” (optional, on Expansion module – used for
dew point sensor)
24 V DC, max. 1 W
Input “1” (optional, on Expansion module – use varies acc. to
application chosen)
Ext. switch input (internal 24 V pull-up)
Input “2” (optional, on Expansion module – use varies acc. to
application chosen)
Ext. switch input (internal 24 V pull-up)
Input “3”, sensor input (optional, on Expansion module)
External sensor, PT 1000 (Danfoss ESM 11)
Dimensions
W: 370 mm, H: 100 mm, D: 53 mm
Conformity declared acc. to following directives
LVD, EMC, RoHS and WEEE
Purpose of control
Individual electronic room temperature control
Method of providing earthing
Factory fitted power cord, incl. PE-conductor
Encapsulation (IP Class)
IP 20
Protection class
Class I
Ambient temperature range, continious use
0 °C to 50 °C
Wireless Thermostat
Purpose of control
Room thermostat for room temperature control
Ambient temperature range, continious use
0 °C to 40 °C
Frequency
869 MHz
Transmission power
<2,5 mW
Encapsulation (IP Class)
IP 21
Supply voltage
2 × 1,5 V AA-Alkaline batteries
Conformity declared acc. to following directives
RED, RoHS, WEEE
Protection class
Class III
24V Wired Thermostat
Purpose of control
Room thermostat for room temperature control
Ambient temperature range, continious use
0 °C to 40 °C
Encapsulation (IP Class)
IP 21
Supply voltage
24 V DC
Conformity declared acc. to following directives
EMC, RoHS, WEEE
Protection class
Class III
External sensor
NTC type, 47 kΩ @ 25 °C (Optional, 088U1110)
Содержание Icon Master Controller 24 V
Страница 1: ...Installation Guide Danfoss Icon Master Controller 24V ...
Страница 2: ......
Страница 76: ...76 Danfoss FEC 2020 03 AN29434614196101 000401 088N2112 00 76 76 76 77 77 78 78 78 78 79 79 79 79 80 80 80 81 ...
Страница 77: ... Danfoss FEC 2020 03 AN29434614196101 000401 088N2112 00 77 CN 7 8 9 10 11 12 13 14 ...
Страница 78: ...78 Danfoss FEC 2020 03 AN29434614196101 000401 088N2112 00 ...
Страница 79: ... Danfoss FEC 2020 03 AN29434614196101 000401 088N2112 00 79 CN ...
Страница 81: ... Danfoss FEC 2020 03 AN29434614196101 000401 088N2112 00 81 CN ...
Страница 100: ......
Страница 101: ......
Страница 102: ...102 Danfoss FEC 2020 03 AN29434614196101 000401 088N2112 00 ...