Motor operates normally in one direction only
Check
Cause
Corrective action
1.
Charge pressure
If charge pressure is low in one direction, the loop
flushing shuttle spool may be sticking to one side.
Measure charge pressure in forward and reverse. If
pressure drops significantly lower in one direction,
inspect and repair loop flushing shuttle spool.
Improper output speed
Check
Cause
Corrective action
1.
Oil level in reservoir
Insufficient hydraulic fluid may reduce system
efficiency.
Fill reservoir to proper level.
8.
Internal leakage
Excess internal leakage may cause lower charge
pressure and affect motor performance including
output speed.
Install loop flushing defeat option and measure case
flow. If case flow is excessive, motor may require major
repair. Contact your Danfoss authorized service
center.
H1F Low output Torque
Check
Cause
Corrective action
8.
Internal leakage
Excess internal leakage may cause charge pressure
to decay, reducing output torque.
Install loop flushing defeat option and monitor case
flow. If case flow is excessive, motor may require major
repair. Contact your Danfoss authorized service
center.