Start up
During and immediately after the motors start up, any hydraulic system must be closely and frequently

checked.

1. To assure best motors performance, run the motors for approximately one hour at 30% of rated

pressure and speed before running at full load.
When running make sure the motors and oil temperature and noise level are sufficiently low. High

temperature or noise level might be symptoms of unforeseen operation conditions that have to be

analyzed and cleared.

2. Check for system leakage and make sure the system is operating satisfactorily.
3. To ensure that the contamination in the hydraulic system does not damage the motors; the following

procedure is recommended after a brief period in operation:

a) After a brief period in operation, have a hydraulic fluid specimen analyzed for the required

cleanliness level.

b) Replace oil filter or change the hydraulic fluid if the required cleanliness level is not reached.

Operational checks

The product is a component which requires no settings or changes during operation.

The machine/system manufacturer is responsible for the proper project planning of the hydraulic system
and its control.

Danfoss recommends ongoing tests for optimal motors performance.

1. Regularly verify that the temperature of the ambient and the operating oil are those initially

determined.

2. Do not subject the motors to pressure, pressure drop or speeds exceeding the maximum values

stated in the appropriate catalogs.

3. Filter the oil to maintain the grade of contamination at 22/20/16 (ISO 4406-1999) or better.

Maintenance

W

Warning

If maintenance has to be performed in an explosive and hazardous atmosphere, an anti-sparking safety

tool must be used.

User Manual

ATEX H1 Bent Axis Variable Displacement Motors

Installation, operation and maintenance

 

12 | 

©

 Danfoss | August 2021

BC382476021584en-000102

Содержание H1B060

Страница 1: ...User Manual ATEX Certified Bent Axis Variable Displacement Motors H1B060 080 110 160 210 250 www danfoss com...

Страница 2: ...visions Date Changed Rev August 2021 Fixed typo and removed old Declaration of Conformity 0102 June 2021 First edition 0101 User Manual ATEX H1 Bent Axis Variable Displacement Motors 2 Danfoss August...

Страница 3: ...fluids 8 Viscosity and temperature for H1B motors 8 Ambient temperature 9 Oil temperature 9 Viscosity 9 Filtering 9 Installation operation and maintenance Assembly of H1B motor to the system 10 Operat...

Страница 4: ...fety of the product depends upon the strict observation of the indications given in this User Manual in particular it is necessary to Always operate within allowed product working operating conditions...

Страница 5: ...T3 Gc NNA temperature class T3 CE Ex II 3G Ex h IIA T4 Gc NNB temperature class T4 CE Ex II 3G Ex h IIA T5 Gc NNC temperature class T5 For detailed information on selecting the appropriate T codes ple...

Страница 6: ...I Zone 2 gas Equipment Category 3G Temperature class T5 T3 Explosion protection group II A The Conformity Assessment Procedure has to be executed according to Directive 2014 34 EU annex VIII Modul A I...

Страница 7: ...Maximum oil temperature Maximum ambient temperature 20 C 64 F 40 C 104 F 60 C 140 F 20 C 68 F T5 T5 T5 40 C 104 F T5 T5 T4 60 C 140 F T5 T4 T4 80 C 176 F T4 T4 T3 115 C 239 F T4 T3 T3 Ambient oil tem...

Страница 8: ...a Viscosity Intermittent1 5 mm2 sec 42 SUS Minimum 7 mm2 sec 49 SUS Recommended range 12 80 mm2 66 371 SUS Maximum cold start 2 1600 mm2 sec 7416 SUS Temperature Minimum cold start 2 40 C 40 F Maximum...

Страница 9: ...commended range for maximum efficiency and bearing life Minimum viscosity should only occur during brief occasions of maximum ambient temperature and severe duty cycle operation Maximum viscosity shou...

Страница 10: ...for Group 11G Make sure that all type of accessory installed on the motor are ATEX specified and have been installed in accordance with ATEX requirements There are no creeping metal elements external...

Страница 11: ...let pressure in the rear port CCW CW P006032 B A Generic illustration shown 3 Select the hydraulic fluid as specified in Oil types Operating fluids 4 Ensure full contact between motors mounting flange...

Страница 12: ...liness level b Replace oil filter or change the hydraulic fluid if the required cleanliness level is not reached Operational checks The product is a component which requires no settings or changes dur...

Страница 13: ...bad smell acidity increase and because of the generation of sludge inside the tank In case symptoms of this kind are detected the system oil must be immediately changed Water presence The presence of...

Страница 14: ...cause injury to the technician or bystanders To protect against unintended movement secure the machine or disable disconnect the mechanism while servicing Follow the manufacturers instructions for sec...

Страница 15: ...nfoss Power Solutions US Company 2800 East 13th Street Ames IA 50010 USA Phone 1 515 239 6000 Danfoss Power Solutions Trading Shanghai Co Ltd Building 22 No 1000 Jin Hai Rd Jin Qiao Pudong New Distric...

Отзывы: