![Danfoss H1 Series Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/danfoss/h1-series/h1-series_basic-information_3453306009.webp)
Charge Pressure Relief Valve (CPRV)
The charge pressure relief valve is a direct acting poppet valve which opens and discharges fluid to the
pump case when pressure exceeds a designated level. The charge pressure relief valve maintains charge
pressure at a designated level above case pressure. This level is nominally set with the pump running at
1800 rpm.
In forward or reverse, charge pressure will be slightly lower than when in neutral position. The charge
pressure relief valve setting is specified on the model code of the pump. Typical charge pressure increase
from 1.2 - 1.5 bar per 10 l/min [17.4 - 21.8 psi per 2.64 US gal/min]. For external charge flow the CPRV is
set according to the table below:
Charge pressure relief valve flow setting for external charge supply
Single 045/053
15 l/min
3.9 US gal/min
Tandem 045/053
30 l/min
7.9 US gal/min
Single 060/068/069/078/089/100/115/130/147/165
22.7 l/min
6.0 US gal/min
Single 210/250
40.0 l/min
106 US gal/min
System schematic, single pump
A
B
MA
S
M3
C2
C1
M4
M5
MB
L4
L2
M6 1
2
R2
R1
M14
F00B F00A
CW
P003 418E
System schematic, tandem pump
C1
C1
C2
C2
M14
M14
CW
F00B F00A
F00B
F00A
A
B
MA
E C D MD
MB
M3
L3
MC
M4
M5
M4
M5
PTO
X7
P003 207E
Basic Information
H1 Axial Piston Pumps, Single and Tandem
Operation
©
Danfoss | April 2017