![Danfoss H1 078 Скачать руководство пользователя страница 41](http://html1.mh-extra.com/html/danfoss/h1-078/h1-078_service-manual_3664242041.webp)
1. Install a new gasket (D150).
Proper Screen Orientation
P106 618E
D084
D084
Incorrect screen
orientation
Correct screen
orientation
D094
2. If you removed screen (D084), install a new one. Install with the mesh facing outward (see drawing).
Install retaining ring (D098).
3. If previously removed, install orifices (F100) using a 3 mm internal hex wrench. Torque to 2.5 N•m [1.8
lbf•ft].
4. Install the control module and six cap screws (D250).
5. Using a 5 mm internal hex wrench, torque the cap screws (D250) to 13.3 N•m [9.8 lbf•ft].
Remove plug on top of control to ensure the swashplate feedback pin is properly positioned in the
center of the control module when installing control.
Control Module and Solenoid Removal/Installation
P106 650E
D025
D1
D025A
D025A
D150
5 mm
13.5 N•m
[9.8 lbf•ft]
D250
D050 (3X)
D050 (3X)
D084
5 N•m [4 lbf•ft]
4 mm
5 N•m
[4 lbf•ft]
4 mm
F100 (2X)
D300 (2X)
2.5 N•m
[1.8 lbf•ft]
3 mm
D098
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Minor Repair
©
Danfoss | May 2018
520L0848 | AX00000087en-US0308 | 41