![Danfoss FP715 Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/danfoss/fp715/fp715_quick-start-manual_3462550004.webp)
2
Sequence of button presses whilst adjusting time, day and programme settings
Read the section Error free programming first.
Press and r or - to change the time by one minute. Press and hold down + or - to change the time quickly.
NOTE:
The installer has set switches on the rear of the FP715 to select either 24 hour operation (same programme repeated each day) or
5/2 day operation (one programme repeated Monday to Friday with a different programme repeated Saturday and Sunday) or 7 day operation
( a different programme for each day). The installer has also selected either 2 ON/OFFs or 3 ON/OFFs per day
SELECTING THE OPERATING MODE
Behind the flap are two SELECT buttons, one each for Central
Heating (
) and Hot Water (
).
The operating modes available are:
ON
- The output is on constantly.
OFF
- The output is off constantly, 1HR is pressed.
AUTO
- The output switches on and off to the set programme.
ALLDAY
- The output switches on at the 1st ON time and stays on
until the last OFF time.
MANUAL OVERRIDES
While in OFF, AUTO or ALLDAY modes the plus one hour (+1HR)
button can be used to switch from off to on for just one hour, or to
extend an existing on period by one hour. The extra hour is cancelled
by pressing the button again, pressing the MAN button, or when an on
event is reached.
While in AUTO or ALLDAY modes pressing the manual (MAN) button
will switch an output which is on to off, and vice versa. This over-ride
will last only until the next programmed switching event is reached,
when the automatic programme will resume control, or until the button
is pressed again.
When the above overrides are selected a bar appears in the display
against the appropriate legend.
Button Sequence
FP715
Typical Displays
Step
Press
Action
1
PROG
To enter programming mode (Fig 2)
2
DAY
To select day of week, repeat until display shows
current day (Fig 2)
3
+ or -
To adjust time of day (Fig 2)
4
PROG
To enter CH ON/OFF programming mode (Fig 3)
5
+ or -
To adjust 1st CH ON time (setting no 1, Fig 3)
6
NEXT
To step to 1st CH OFF time (setting no 2, Fig 4)
7
+ or -
To adjust 1st CH OFF time (setting no 2, Fig 4)
8
NEXT
Repeat step 5-7 until all ON/OFF times are as
required
9
-
If unit is set for 24 hour operation, go to step 13, otherwise
go to step 10
10
DAY
To advance to next day. If a different programme from
previous day is required go back to step 7.
If the same programme as previous day is required
go to step 11.
11
COPY
To copy previous days' programmes to current day
12
-
Repeat steps 10 an d11 until all days are programmed
13
PROG
To enter HW ON/OFF programming mode
14
+ or -
To adjust 1st HW ON time (setting no 1)
15
NEXT
To step to 1st HW OFF time
16
+ or -
To adjust 1st HW OFF time
17
NEXT
Repeat steps 14 - 16 until all HW events are set
18
PROG
To return to RUN mode
Fig 1
Fig 2
Fig 3
Fig 4
Fig 5
Fig 6
setting no
setting no
setting no
setting no