0-51 Set-up Copy
Option:
Function:
[0]
*
No copy
No function
[1]
Copy to set-
up 1
Copies all parameters in the present
Programming Set-up (defined in
0-11 Programming Set-up
) to Set-up 1.
[2]
Copy to set-
up 2
Copies all parameters in the present
Programming Set-up (defined in
0-11 Programming Set-up
) to Set-up 2.
[3]
Copy to set-
up 3
Copies all parameters in the present
Programming Set-up (defined in
0-11 Programming Set-up
) to Set-up 3.
[4]
Copy to set-
up 4
Copies all parameters in the present
Programming Set-up (defined in
0-11 Programming Set-up
) to Set-up 4.
[9]
Copy to all
Copies the parameters in the present set-up
over to each of the set-ups 1 to 4.
3.2.7 0-6* Password
0-60 Main Menu Password
Range:
Function:
100 N/A
*
[0 - 999 N/
A]
Define the password for access to the main
menu via the [Main Menu] key. If
0-61 Access to Main Menu w/o Password
is
set to
Full access
[0], this parameter will be
ignored.
0-61 Access to Main Menu w/o Password
Option:
Function:
[0]
*
Full access
Disables password defined in
[1]
LCP: Read only Prevent unauthorized editing of main menu
parameters.
[2]
LCP: No access Prevent unauthorized viewing and editing of
main menu parameters.
[3]
Bus: Read only Read-only functions for parameters on the
serial communication bus and/or FC
standard bus.
[4]
Bus: No access No access to parameters is allowed via the
serial communication bus and/or FC
standard bus.
[5]
All: Read only
Read-only function for parameters on the
LCP, serial communication bus or FC
standard bus.
[6]
All: No access
No access from LCP, serial communication
bus or FC standard bus is allowed.
If
Full access
0-65 Personal Menu Password
and
0-66 Access to Personal
Menu w/o Password
will be ignored.
0-65 Quick Menu Password
Range:
Function:
200
*
[-9999 -
9999 ]
Define the password for access to the quick
menu via the [Quick Menu] key. If
is set to
Full
access
[0], this parameter will be ignored.
0-66 Access to Quick Menu w/o Password
Option:
Function:
[0]
*
Full access
Disables the password defined in
[1]
LCP: Read only Prevents unauthorized editing of quick
menu parameters.
[2]
LCP: No access Prevents unauthorized viewing and editing
of quick menu parameters.
[3]
Bus: Read only Read only functions for quick menu
parameters on serial communication bus
and/ or FC standard bus.
[4]
Bus: No access No access to quick menu parameters is
allowed via serial communication bus and/
or FC standard bus.
[5]
All: Read only
read only function for quick menu
parameters on LCP, serial communication
bus or FC standard bus.
[6]
All: No access
No access from LCP, serial communication
bus or FC standard bus is allowed.
If
0-61 Access to Main Menu w/o Password
is set to
Full access
[0], then this parameter will be ignored.
0-67 Bus Password Access
Range:
Function:
0
*
[0 - 9999 ] Writing to this parameter enables users to unlock
the adjustable frequency drive from bus/ MCT10.
Parameter Descriptions
FC 300 Programming Guide
MG.33.MA.22 - VLT
®
is a registered Danfoss trademark
3-11