6.5 Micrometer adjustment
If the measured forming dimensions of the workpiece deviate from
the forming dimensions of the crimping die when the micrometer is
set to zero, the micrometer must be readjusted.
1.
Release the screws on the cover.
2.
Remove the cover (see “Annex” in Section 9).
3.
Loosen the counter-nut (1) of the contact screw (2).
4.
Adjust the contact screw (2).
2.5 revolutions of the contact screw correspond to 1 mm change in
the forming dimension.
V
5.
Remount the enclosure/front panel.
6.
Test the crimping process and readjust if necessary.