5.8 Emergency stop
In case of an emergency
Immediately deactivate the emergency-stop switch in cases of
emergency. The crimping tool movement will be stopped. The drive
unit is shut down.
Restart after and emergency
WARNING!
Risk of injuries!
The emergency-stop button was probably activated due to the
occurrence of a hazardous situation. A restart of the machine
may cause injuries if the hazardous situation has not yet been
remedied!
• Remedy the hazardous situation before a restart.
1.
Remedy the cause of the emergency stop.
2.
Activate the emergency-stop switch.
5.9 Cleaning
ATTENTION!
Risk of damage to machinery!
If the machine is cleaned with a steam jet or compressed air, dirt
and water may ingress in the machine and cause serious da-
mage.
• Do not use a steam jet to clean the machine.
• Do not use compressed air to clean the machine.