Danfoss ET1000 Скачать руководство пользователя страница 3

Danfoss ET1000 Crimp machine operator’s manual

AQ418954799548en-000101

© Danfoss ET1000 Crimp machine operator’s manual | 2022.06.  | 3

Specifications and accessories 

ET1000 Crimp machine and accessories

NOTE:

Your new crimp machine
has been calibrated and filled with 
hydraulic oil in the factory. Do not 
remove any plugs or caps until 
necessary. Excess air in the hydraulic 
system may cause erratic cylinder 
movement during retraction. Refer 
to the Setup and Assembly section 
for instructions on removing air 
from the hydraulic system.

Specifications

Crimper Dimensions:
22” tall x 16” width x 14” deep
Weight: 70 lbs. (machine & stand 
only)

Pump Requirements:
•  Reservoir Capacity: 
  36 cu. in (590 cc)
•  Pressure Rating:
  10,000 psi (690 bar)
•  The air/hydraulic pump
  requires a minimum of
  100psi to operate at maxi- 
  mum efficiency.

Hose Production Capacity:
Crimps up to -16 in braided and spi-
ral hydraulic hose with core tooling 
and up to -20 in braided hose using 
non-core, specialty tooling.

Accessories

•  Bench mount bracket  
  (Part # ET1000C-0001)

•  Truck/wall mount bracket  
  (Part # ET1000C-0021)

•  1.5 oz. tube high efficiency  
  PTFE grease ( 
  Part # T-400-G)

•  16 oz. can high efficiency  
  PTFE grease  
  (Part # FF91455)

•  Handle kit includes 2 easy  
  grip handles with mounting  
 hardware 
  (Part # ET1187C-0028)

•  Portability kit includes  
  2 easy grip handles with  
  mounting hardware, longer  

  hose assembly, and FF  
  series quick disconnect  
 couplings 
  (Part # ET1187C-0029)

Available pump options:

•  Hand pump kit  
  (Part #ET1000PK-001)

•  Air/hydraulic pump kit  
  (Part #ET1000PK-002)

•  110v electric pump kit  
  (Part #ET1000PK-003)

•  12v DC electric pump kit  
  (Part #ET1000PK-004)

Note: These pump kits include the pump, 
connecting hose assembly, and all of the 
adapters necessary to connect the pump to 
the ET1000 crimp machine.

1.

  

 

Your new ET1000 crimp 
machine comes disassembled 
for ease of shipment. Before 
use, the machine must be 
assembled to the base with the 
supplied quick release pins. Pins 
should be installed from the 
inside of the machine to avoid 
any contact between the pins 
and tooling during the crimping 
process (See Figure A).

2.

 

 

Remove the plug from the top 
cylinder port and install the 
–06 size ORB,90 degree adapter 
using 23-24 ft. lbs. assembly 
torque. Orient the adapter so 
that it points to the rear of the 

crimp machine, away from the 
operator.

3.

 

 

Install the pump connecting 
hose assembly to the cylinder 
adapter with the –06 size 37 
degree swivel nut fittings using 
18-20 ft. lbs. assembly torque.

4. 

 

 

Do not exceed an 8” minimum 
bend radius of the pump con-
necting hose when attaching the 
hose to the pump and cylinder.

5.

 

 

 

If using your own pump, make 
sure it has the requirements list-
ed in the Specifications section 
above.

6. 

 

 

Place the pump on the work 
surface to either side of the 
crimp machine. Install the 90 
degree adapter to the pump 
pressure port (Male NPTF threads 
should be tightened following 
the hex-marking procedure of 2 
to 3 turns past hand tight).

7. 

 

 

Remove excess air from the 
hydraulic system. This can be 
accomplished by placing the 
pump at a higher level than the 
cylinder and cycling the machine 
approximately five times.

8.

 

 

 

Secure the machine frame to 
a stable work surface using lag 
screws or other suitable fasten-
ers.

Setup and Assembly

Hand pump

Air/hydraulic  

pump 

110v electric 

pump

12v DC electric

pump

Figure A

Содержание ET1000

Страница 1: ...Operator s manual Danfoss ET1000 Crimp machine...

Страница 2: ...is neither recommended nor autho rized by Danfoss Safety Instructions 1 PREVENT UNAUTHORIZED OPERATION Do not permit anyone to operate this equip ment unless they have read and thoroughly understand...

Страница 3: ...T1000PK 003 12v DC electric pump kit Part ET1000PK 004 Note These pump kits include the pump connecting hose assembly and all of the adapters necessary to connect the pump to the ET1000 crimp machine...

Страница 4: ...ace the spacer ring in the appro priate position on top of the collet assembly either flat side up or flat side down as referenced in the PowerSource crimp spec tool Step 1A If using smaller collets w...

Страница 5: ...tting hose combina tions require full pump reser voir capacity to complete the crimp cycle The oil level in the fluid reservoir of the hydraulic pump should be checked peri odically and refilled as re...

Страница 6: ...Slide Plate 1 10 140 06925 Bushing Slide Plate 2 11 ET1000C 0006 Pusher 1 12 140 06602 Detent Screw 1 13 140 15984 01 Flat Head Cap Screw 2 14 140 15984 03 Flat Head Cap Screw 2 Item Part No Descript...

Страница 7: ...Danfoss ET1000 Crimp machine operator s manual AQ418954799548en 000101 Danfoss ET1000 Crimp machine operator s manual 2022 06 7...

Страница 8: ...ss hoses fittings and tooling provide the ultimate fluid conveyance solutions for a variety of equipment and applications around the world We proudly engineer to support a sustainable future for tomor...

Отзывы: