Installation guide - ERC 211

8 - Technical Data

FEATURES

DESCRIPTION

Purpose of control

Operating temperature sensing control suitable for incorporation into commercial air-
conditioning and refrigeration applications

Construction of control

Incorporated control

Input

Low voltage, regulated, galvanically isolated, 115 V AC or 230 V AC, 50/60 Hz input

Rated power

Less than 0.7 W

Inputs

Sensor inputs, Digital inputs, Programming key
Connected to SELV limited energy <15 W

Types of sensors allowed

NTC 5000 Ohms at 25 °C (beta = 3,980 at 25/100 °C - EKS 211 for example)
NTC 10000 Ohms at 25 °C (beta = 3,435 at 25/85 °C - EKS 221 for example)
PTC 990 Ohms at 25 °C (EKS 111 for example)
Pt1000 (AKS 11, AKS 12, AKS 21 for example)

Sensors in “Kit Solution”

NTC 10000 Ohms at 25 °C, 1.5 m cable

Precision

Measuring range:
-40 – 105 °C (-40 – 221 °F)
Controller accuracy:
+/-1 K below -35 °C,
+/-0.5 K between -35 – 25 °C, +/-1 K above 25 °C

Type of action

1B (relay)

Output

Compressor relay DO1:
16 A, 16 (16) A, EN 60730-1
10 FLA / 60 LRA at 230 V, UL60730-1
16 FLA / 72 LRA at 115 V, UL60730-1

Display

LED 3-figure display, decimal point and multifunction icons, °C + °F scale

Operating Conditions

-10 – 55 °C (14 – 131 °F), 90% Rh

Storage conditions

-40 – 70 °C (-40 – 158 °F), 90% Rh

Protection

Front: IP65 (with seal)
Rear: IP00

Environmental data

Pollution degree II, condensate free

Overvoltage category

II - 230 V supply version - (ENEC, UL recognized)
III - 115 V supply version - (UL recognized)

Heat and fire resistant

Category D (UL94-V0)
Temperature for ball pressure test statement “According to Annex G”
(EN 60730-1)

EMC category

Category I

Certifications

UL acknowledgement (USA and Canada) (UL 60730-1)
ENEC (EN 60730-1)
CQC
EC (LVD and EMC Directives)
EAC (GHOST)
NSF
ROHS2.0
HACCP temperature monitoring in compliance with EN134785 Class I if used with sensor AKS 12

Содержание ERC 211

Страница 1: ...r mount clip fixing Drilling template Dimensions mm Assembly Wiring diagram The ERC 211 is a smart multipurpose integrated refrigeration controller with temperature and defrost management available with 1 relay This controller is for Operating temperature sensing control suitable for refrigeration and heating applications Integrated control has been designed to fulfil today s requirements for comm...

Страница 2: ...isplay shows the default value for example AP0 blinking Select the type of application by pressing UP DOWN and then SET to confirm The regulator presets the parameter values on the basis of the application selected and hides any irrelevant parameters Tip you can easily switch from AP0 to AP6 and therefore select the simplified parameters list by pressing the UP button circular list STEP 4 Select t...

Страница 3: ...e parameter groups To scroll the parameter names 5 Quick configuration with cFg menu Press SET for three seconds to open the parameter groups Select the cFg menu and press SET to open The first menu r12 main switch is displayed Set the main switch to OFF r12 0 to change the preinstalled application Press UP DOWN to scroll through the parameters list Configure the parameter o61 to select a preinsta...

Страница 4: ... PULL DOWN press for 3 seconds to stop pull down Temperature and alarm codes alternate flashes until the alarm is resolved The alarm bell is shown After 5 minutes of inactivity the keypad will be locked if P76 YES When the keypad is locked if any key is selected LoC appears on the display Press UP and DOWN buttons simultaneously for 3 seconds to unlock the keyboard unl is displayed for 3 seconds S...

Страница 5: ...NTC 10000 Ohms at 25 C 1 5 m cable Precision Measuring range 40 105 C 40 221 F Controller accuracy 1 K below 35 C 0 5 K between 35 25 C 1 K above 25 C Type of action 1B relay Output Compressor relay DO1 16 A 16 16 A EN 60730 1 10 FLA 60 LRA at 230 V UL60730 1 16 FLA 72 LRA at 115 V UL60730 1 Display LED 3 figure display decimal point and multifunction icons C F scale Operating Conditions 10 55 C 1...

Страница 6: ...12 1 1 1 1 1 1 1 Night set back offset temperature during night mode r13 50 0 50 0 K 0 0 0 0 0 0 0 0 0 0 0 0 Thermostat reference displacement offset temperature r40 50 0 50 0 K 0 0 0 0 0 0 0 0 0 0 Pull down duration r96 0 960 min 0 0 0 Pull down limit temperature r97 100 0 200 0 C F 0 0 0 0 0 0 Alarm A Delay for temperature alarm during normal conditions A03 0 240 min 30 45 45 45 30 30 Delay for ...

Страница 7: ... not used Sdc status display output doo door alarm with resumption doA dooralarmwithoutresumption SCH main switch nig day night mode rFd reference displacement EAL external alarm dEF defrost Pud pull down Sc condenser sensor o02 oFF Sc oFF oFF oFF oFF oFF oFF Serial address o03 0 247 0 0 0 0 0 Password o05 no 999 no no no no no no Sensor type selection n5 NTC 5 K n10 NTC 10 K Ptc PTC Pt1 Pt1000 o0...

Страница 8: ...FF S14 defrosting state S15 fandelaystateafterdefrost S17 door open DI input S20 emergency cooling S25 manual control of outputs S30 continous cycle Pull down S32 delay of outputs at power up u00 S0 S32 Air temperature Sair u01 100 0 200 0 C F Read the present regulation reference u02 100 0 200 0 C F DI1 input u10 oFF on Status of night operation u13 oFF on Condenser temperature Sc U09 100 0 200 0...

Отзывы: