Compressor
Table 19: Compressor
Function
Code
Min.
Max.
Unit
AP0
AP1
AP2
AP3
AP4
AP5
Compressor
c--
Compressor minimum ON time
C01
0
30
min
0.0
0.0
0.0
0.0
0.0
0.0
Compressor minimum OFF time
C02
0
30
min
2.0
2.0
2.0
2.0
2.0
2.0
Compressor OFF delay at open door
C04
0
900
sec
900.0
900.0
900.0
900.0
900.0
60.0
Zero crossing selection (YES / no)
C70
no
YES
YES
YES
YES
YES
YES
YES
(1)
(1)
This option is a default setting in the controller and cannot be changed.
(1)
This option is a default setting in the controller and cannot be changed.
Others
Function
Code
Min.
Max.
Unit
AP0
AP1
AP2
AP3
AP4
AP5
Others
o--
Delay of outputs at startup
o01
0
600
sec
10
10
10
10
10
10
(1)
DI1 configuration
nC= Not configured; Sdc = Status display output, doo = Door
alarm with resumption, doA = Door alarm without resumption,
SCH = Main switch, nig = Day/ Night mode, rFd = Reference dis-
plasement, EAL = External alarm, dEF = Defrost, Pud = Pull
down; Sc = Condensor Sensor
o02
oFF
Sc
oFF
oFF
oFF
oFF
oFF
oFF
Serial address
o03
0
247
No
0
0
0
0
0
-
Password
o05
0
999
No
0
0
0
0
0
0
Sensor type selection (n5=NTC 5K, n10=NTC10K, ptc=PTC,
pt1=PT1000)
o06
(2)
n5
ptc
n10
n10
n10
n10
n10
n10
Cooling/Heating (rE=Cooling, Ht= Heating)
o07
rE
Ht
rE
rE
rE
Ht
rE
Display Resolution
o15
0.1
1.0
0.1
0.1
0.1
0.1
0.1
Predefined applications
o61
AP0
AP5
AP0
AP1
AP2
AP3
AP4
AP5
Save settings as factory
WARNING:
The earlier factory settings are overwritten
o67
no
YES
no
no
no
no
no
-
Display during defrost
Air=actual air temperature, FrE=freezed temperature, -d-="-d-"
is displayed
o91
-d-
Air
-d-
-
-d-
-d-
-
-d-
(1)
This option is a default setting in the controller and cannot be changed.
(2)
This parameter can only be set when regulation is stopped, i.e. “r12” is set to 0
(1)
This option is a default setting in the controller and cannot be changed.
(2)
This parameter can only be set when regulation is stopped, i.e. “r12” is set to 0
Polarity
Table 20: Polarity
Function
Code
Min.
Max.
Unit
AP0
AP1
AP2
AP3
AP4
AP5
Polarity
P--
DI1 input polarity (nc/no)
no = normally open
nc = normally closed
P73
no
nc
no
no
no
no
no
no
Key board lock (no / yes)(0=no, 1=yes)
P76
no
YES
no
no
no
no
no
-
Parameters: ERC 213
Configuration
Table 21: Configuration
Function
Code
Min.
Max.
Unit
AP0
AP1
AP2
AP3
AP4
AP5
AP6
AP7
Configuration
cFg
Main switch (-1=Service, 0=OFF, 1=ON)
r12
-1
1
1
1
1
1
1
1
1
1
Predefined applications
o61
(2)
AP0
AP7
AP0
AP1
AP2
AP3
AP4
AP5
AP6
AP7
Electronic refrigeration control, type ERC 21X
© Danfoss | Climate Solutions | 2023.01
BC194286421698en-000901 | 24